3
SPECIFICATIONS
RATED PERFORMANCE:
ECHOTec Model
Gallons per hour
Liters per hour
400
–
BML
–
2
21
80
600
–
BML
–
3
33
126
800
–
BML
–
4
42
160
500
–
BML
–
1
22
83
900
–
BML
–
2
40
150
1200
–
BML
–
3
53
200
1500
–
BML
–
4
64
242
Reverse Osmosis performance varies with the feed water temperature and salinity.
The rated performance is tested at 26
C / 80
F water temperature and 33g NaCl/ltr.
RO MEMBRANE TYPE:
Standard size high rejection TFC Polyamide, thin film composite, spiral wound, single pass reverse osmosis
element.
PRODUCT WATER QUALITY:
minimum 500 ppm TDS
FEED WATER SALINITY RANGE:
up to 50,000 ppm TDS ( NaCl )
PH RANGE:
4
–
11
CHLORINE TOLERANCE:
1000 ppm hours
FEED WATER PRESSURE:
5”Hg to 60 psi
OPERATING PRESSURE:
900 psi
FEED WATER TEMPERATURE RANGE:
min. 33
F / 0.5
C, max 113
F / 45
C
ELECTRICAL POWER REQUIREMENTS:
8 amps at 12 VDC