background image

 

11

 

 

INSTALLATION INSTRUCTION 

 OPTIONAL EQUIPMENT 

 

 

BOOST PUMP  

 

Install the submersible boost pump with the electric motor sideways (horizontal) 

below

 the water line, in 

between the sea strainer and the pre-filter(s).  The intake is at the center of the pump.  The outlet should 
ideally point upwards or sideways with the fitting to the top to prevent air pockets. 
 
Avoid elbows/90

˚

 fittings in your plumbing if possible.  The complete pump head can be turned in case the 

outlet direction is not suitable for your installation. 
 
The ECHOTec 

“Orbital” Magnetic Drive Pumps eliminate the conventional shaft seals found in most pumps.  

This means that there is no rotating seal to wear and allow the liquid being pumped to leak out. 
 
We rely on the liquid being pumped to lubricate the impeller-magnet assembly spinning on the stationary 
spindle. If the pump is run dry for longer than 10 minutes, the assembly 

may “freeze” onto the spindle.

 

 
All pumps can be serviced with the use of a screwdriver.  The only moving part in the pump other than the 
motor  is  the  impeller-magnet  assembly.    This  assembly  rotates  on  a  stationary  spindle  and  up  against  a 
thrust washer. 
 

Note:

  The boost pump includes the 5 micron pre-filter option. 

 

 

5 MICRON PRE-FILTER   

 

Connect  the  filter  housing  with  the  supplied  ¾”  nylon  nipple  to  the  standard  filter  housing  and 

reconnect the reinforced vinyl hose.  The 5micron cartridge has to be installed as the second filter in 
flow direction.   

 

5 MICRON PRE FILTER WITH LOW PRESSURE GAUGE 

 

The optional 5micron pre filter housing with low pressure gauge has to be installed as a second filter in 
flow direction. 

 

FRESHWATER FLUSH SYSTEM  

 

Install the active carbon filter housing at an easily accessible location close to your seawater intake line 
and any pressurized water line. Connect the fitting on the shut off valve of the carbon filter housing to 

your boats’ 

pressurized water line. 

 
Connect  the  filter  outlet  to  the  supplied  T-connector.  Connect  the  two  remaining  ports  of  the  T-
connector to the outlet of the storage/cleaning valve on the pre-filter housing and to the intake of the 
high pressure pump (refer to the flow diagram).   
 

Содержание 400-BMS-1

Страница 1: ...tures Options and Accessories 6 Flow Diagram 7 10 Installation Instructions 11 Installation Instructions Options 12 13 System Operation Shut Down and Flush Procedure 14 Membrane Storage and Cleaning P...

Страница 2: ...safe drinking water for many years to come if you follow the simple instructions in this owners guide The purpose of this manual is to allow you to become familiar with each component of your new ECH...

Страница 3: ...ce is tested at 26 C 80 F water temperature and 33g NaCl ltr RO MEMBRANE TYPE Standard size high rejection TFC Polyamide thin film composite spiral wound single pass reverse osmosis element PRODUCT WA...

Страница 4: ...1 Pressure control valve 1 High pressure gauge 1 Product flow meter 1 Diverter 3 way valve 1 Breaker without boost pump or 2 Breakers with boost pump 6 1 Hardener pH neutralizer kit with mineral eleme...

Страница 5: ...as a second filter in flow direction Maintenance Kit 10 Pre filters 5 and or 20 microns 1 Spare sea strainer screen 2 Active carbon filters fresh water flush 1ltr High pressure pump oil Extended Maint...

Страница 6: ...6 FLOW DIAGRAM Shown with Optional Equipment...

Страница 7: ...225 RPM The high pressure pump can run on lower RPM This will decrease the specified production only Position the high pressure pump horizontal with the dipstick up The pump can turn in either directi...

Страница 8: ...mechanical stress do not mount the sea strainer directly to the sea cock Connect the barbed fittings with the supplied coil reinforced intake hose and secure all hoses below water level with two hose...

Страница 9: ...ne housing to the pressure control valve in the control panel Do not over tighten the high pressure fittings They are O ring sealed and need little torque to lock only CAUTION When connecting the high...

Страница 10: ...alizer housing at a serviceable location in line with the product water tubing from the diverter valve on the control panel to the freshwater storage tank Refer to flow diagram on page 6 Note Observe...

Страница 11: ...a screwdriver The only moving part in the pump other than the motor is the impeller magnet assembly This assembly rotates on a stationary spindle and up against a thrust washer Note The boost pump inc...

Страница 12: ...eaning storage valve to the pre filter position towards the filter 4 Set the diverter valve to sample position left 5 Switch on the boost pump optional 6 Switch on the high pressure pump 7 Flush the a...

Страница 13: ...he brine at the outlet becomes fresh PRE FILTER BACKWASH PROCEDURE As part of a long term storage you may remove the pre filter cartridges from the housings or perform a pre filter backwash procedure...

Страница 14: ...cleaning of the membrane will reduce the performance of your water maker A drop in production of approximately 10 is normal and expected during the first year of operation Note Do not clean when prod...

Страница 15: ...PSI No Boost pump pressure lower than 5 Hg Hardener pH neutralizer Replace or refilled with the mineral mix of another cartridge when 25 of the content has been dissolved to guaranty sufficient conta...

Страница 16: ...agnetic clutch slips Tighten all hose clamps Reseal NPT fittings Move through hull fitting to lower location Bad electrical contact Test voltage directly at clutch connection when clutch is engaged Ex...

Страница 17: ...e pliers pull the membrane element on the product tube in flow direction 6b Push out the remaining end plug from the opposite side with a pipe boat hook etc If the product port is mounted on the high...

Страница 18: ...urn ring 25 pressure ring 24 and V sleeve with support ring 23 from the valve casing 26 Remove the V sleeve 23 from the seal case 20 Inspect all parts including O ring 21 for wear and replace if neces...

Страница 19: ...otate the seal case as well so that the weep holes are down at the six o clock position Change the oil fill and the oil drain plugs Refer to the repair instructions as necessary for the proper assembl...

Страница 20: ...ho Marine Ltd will repair or replace at its option the product or component therein which upon examination by Echo Marine shall appear to be defective or not up to factory specifications To obtain war...

Страница 21: ...rse osmosis membrane element s installed However if the ECHOTec system will not be put to use within 10 months of shipment there is a potential danger of the membrane element s fouling Therefore we of...

Отзывы: