Page 12 of 20
After the module groups have a sequence selected, a flash pattern rate can be chosen. The default rates are as follows in TABLE 10.
Level Mode Default Flash Rate by Module Group - Synchronized
Module Group
L1
L2
L3
Front
Quad 75 FPM Quad 75 FPM
Cycle
Rear
Quad 75 FPM Quad 75 FPM
Cycle
L1 + L2
L1 + L3
L2 + L3
L1 + L2 + L3
Front
Quad 75 FPM Cycle
Cycle
Cycle
Rear
Quad 75 FPM Left/Right
Cycle
Cycle
TABLE 10
To change a Module group’s flash pattern rate selection:
1. Power-up the lightbar and apply +power to a single level mode (see Table 2) in the 16 conductor cable.
2. Momentarily touch the BLK/RED Pattern select wire and the appropriate Module group wire, shown in Table 11, to +power to cycle through
the flash pattern rates shown in shown in Table 12. Hold the wires to +power for more than 4 seconds to return to the factory default
setting.
Module Group Flash Rate Wires - Synchronized
Function Wire Color
Module Group
GRN/WHT
Front
BLU/BLK
Rear
TABLE 11
Module Group Flash Patterns -
Unsynchronized
Order Flash Pattern
1
Double 75 FPM
2
Triple 75 FPM
3
Quad 75 FPM
4
Quint 75 FPM
5
Triple Pop 75 FPM
6
Quad Pop 75 FPM
7
Single 150 FPM
8
Double 150 FPM
9
Triple 150 FPM
10
Quad 150 FPM
11
Quint 150 FPM
12
Triple Pop 150 FPM
13
Quad Pop 150 FPM
14
Single 375 FPM
15
NFPA Quad 77 FPM
16
Cycle Flash
TABLE 12