Emergency Mode Flash Pattern Selection

There are seven customizable emergency flash pattern modes available based on the wire combinations shown in Table 2. When using 

individual switches, make sure to configure all possible switch combinations. The default flash setting is unsynchronized which allows each 

module group to be configured separately and the lightbar to flash in an unsynchronized pattern. Steps to synchronize the module groups 

together are detailed in later sections.

The module groups in each mode come with the default flash patterns shown in Table 3

TABLE 2

Level Mode Combinations

Function Wire Color

Flash Pattern Modes

GRN/BLK

L1

WHT/BLK

L2

GRN/BLK & WHT/BLK

L1 + L2

RED/BLK

L3

GRN/BLK & RED/BLK

L1 + L3

WHT/BLK & RED/BLK

L2 + L3

GRN/BLK, WHT/BLK, & RED/BLK

L1 + L2 + L3

TABLE 3

Level Mode Default Flash Patterns by Group - Unsynchronized

Module Group

L1

L2

L3

Front Outboard

Off

Quad 75 FPM

Cycle Flash

Front Inboard

Off

Quad 75 FPM

Cycle Flash

Front Corner

Off

Quad 75 FPM

Cycle Flash

Rear Outboard

Quad 75 FPM

Off

Cycle Flash

Rear Inboard

Quad 75 FPM

Off

Cycle Flash

Rear Center

Quad 75 FPM

Off

Cycle Flash

Rear Corner

Quad 75 FPM

Off

Cycle Flash

Rear End

Quad 75 FPM

Off

Cycle Flash

Takedown/Work Lights*

Off

Quad 75 FPM** Cycle Flash**

Alley Lights

Quad 75 FPM** Quad 75 FPM** Cycle Flash**

L1 + L2

L1 + L3

L2 + L3

L1 + L2 + L3

Front Outboard

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Front Inboard

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Front Corner

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Rear Outboard

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Rear Inboard

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Rear Center

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Rear Corner

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Rear End

Quad 75 FPM

Cycle Flash

Cycle Flash

Cycle Flash

Takedown/Work Lights*

Quad 75 FPM** Cycle Flash**

Cycle Flash**

Cycle Flash**

Alley Lights

Quad 75 FPM** Cycle Flash**

Cycle Flash**

Cycle Flash**

*Takedown/Work lights and alley lights are included in Level Mode operations only when they are multicolor LED modules.  

**Flash patterns will flash primary LED colors only, see Table 4 for details.

Содержание 21 Series

Страница 1: ...dependent flashing and CC centrally controlled IF Independent Flashing indicates the lightbars modules have individual electronic circuits that control their operation each module a group or a pair of...

Страница 2: ...other warning device does not ensure all drivers can or will observe or react to an emergency warning signal Never take the right of way for granted It is your responsibility to be sure you can proce...

Страница 3: ...centers on the roof of the vehicle Remove the lightbar and drill the mounting holes as marked Note The center distance between the mounting holes in an adjustable mounting foot is 11 1 or 281 94 mm 4...

Страница 4: ...ge when possible as shown in FIGURE 4 3 With the mounting hardware positioned mark the location of the mounting hole centers on the roof of the vehicle Remove the lightbar and drill the mounting holes...

Страница 5: ...ied washers and nuts as shown in FIGURE 5 4 With the mounting brackets positioned mark the locations of the mounting hole centers on the roof of the vehicle Remove the bar and drill the mounting holes...

Страница 6: ...lse trip when mounted in hot environments or operated close to their capacity Important This unit is a safety device and it must be connected to its own separate fused power point to assure its contin...

Страница 7: ...test care to ensure that the use of these functions do not diminish the effectiveness of the Emergency Warning signal When the Pattern Select wire is connected to power alone test mode is enabled to e...

Страница 8: ...ner Off Quad 75 FPM Cycle Flash Rear Outboard Quad 75 FPM Off Cycle Flash Rear Inboard Quad 75 FPM Off Cycle Flash Rear Center Quad 75 FPM Off Cycle Flash Rear Corner Quad 75 FPM Off Cycle Flash Rear...

Страница 9: ...ycle through one pattern as detailed in Table 6 The pattern for the module group configured will only be set in the level mode selected Hold the wires to power for more than 4 seconds to return to the...

Страница 10: ...FPM Primary Only 17 Single 150 FPM Primary with Secondary Pop 18 Double 75 FPM Primary Only 19 Double 75 FPM Primary with Secondary Pop 20 Triple Pop 75 FPM Primary Only 21 Triple Pop 75 FPM Primary w...

Страница 11: ...o power to set the level mode to synchronized The four corner modules will turn on each time the lightbar is toggled between unsynchronized and synchronized Module Group Flash Sequence Synchronized Or...

Страница 12: ...nductor cable 2 Momentarily touch the BLK RED Pattern select wire and the appropriate Module group wire shown in Table 11 to power to cycle through the flash pattern rates shown in shown in Table 12 H...

Страница 13: ...Flash Left Right 12 Travelling Ball Flash TABLE 14 Arrowstik End Flash Pattern Selection The lightbar can be ordered with two additional lamps positioned at the outermost ends of the ArrowStik These t...

Страница 14: ...Programming will not work if more than one function is selected 2 Touch the Pattern Select wire BLK RED to power to cycle through the flash patterns shown in Table 16 Hold for longer than 4 seconds to...

Страница 15: ...rd Corners 7 Front Center Inboard Front Inboard Outboard Corners 8 Front Center Inboard Outboard 9 Front Outboard Corners 10 Front Inboard Corners 11 Front Center Corners 12 Front Inboard Outboard Cor...

Страница 16: ...er Primary Only 4 Corners Front Rear Dim Flicker Secondary Only 5 Corners Front Rear Dim Flicker Primary Corners Front and Secondary Rear 6 Left Front Corner Secondary Only 7 Left Rear Corner Secondar...

Страница 17: ...the lens edge and twist the screwdriver to lift the lens 3 When finished reinstall making sure the lens gasket is not damaged or folded Replace the clips by hooking into the bottom lens slot and pres...

Страница 18: ...essories Controller integrated Safety Director for use with centrally controlled modules EZ2127ASCC Controller integrated Safety Director for use with independent flashing modules EZ2127ASIF Driver Bo...

Страница 19: ...d of this document PROBLEM POSSIBLE CAUSE SOLUTION Does not function Poor power or ground connection In CC Lightbars a green light on the central control board should flash when power is first applied...

Страница 20: ...D OR IMPLIED THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FIT NESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT BUYER S SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT O...

Отзывы: