35
11.2.1 - Flame Icon:
When operating between 0% and 50% capacity range, the icon is displayed on the
LCD screen as single bar, whereas it is displayed as two bars when operating between 50% -100% capacity
range.
11.2.2 - Pressure Indicator:
The LCD display shows 0-0,5-1-1,5-2-2,5-3 bar water pressure values. The
values other than these ones are not displayed.
Only when filling after F37 (Low water pressure error) fault,
the pressure value is displayed in the temperature value section.
11.3- Operation Functions
11.3.1- Standby (OFF Mode):
The mode where boiler can be set to standby mode. In this mode, no
requests for heating water and domestic water can be made. To activate the OFF mode, it is necessary to
keep button no. 1 (position selector) pressed for 3 seconds continuously. When -OFF- is displayed on
screen, mode is activated.
11.3.2- Air Purge Mode (AP Mode):
It is the process that the boiler automatically activates to discharge
air in the central heating installation for 160 seconds. In this mode, "AP" is displayed on the screen. The
circulation pump runs for 15 seconds and then stops every 5 seconds in intervals of every 20 seconds. The
three-way valve motor also changes position between a CH-DHW in 40 seconds. The situations where this
mode is activated is listed here below.
Once the boiler is powered for the first time or after the electricity has been switched off and on,
After the reset operation following the overheating fault (E03),
After elimination of high water pressure (F40) or low water pressure (F37) error,
CAUTION: Do not press 'RESET' while AP mode is active.
11.3.3- Winter mode-Radiator Heating:
If the boiler in the standby position is set to the winter position,
it will heat the water in the heating circuit until the domestic water is needed. In the winter mode, both the
tap and the radiator icon are displayed on the LCD screen.
When a request for heating is made for radiator, radiator icon flashes (once/second), tap icon stays fixed.
When a request for domestic water is made, tap icon flashes (once/second), radiator icon stays fixed. In
this mode, radiator heating circuit's temperature can be set between 30-
80 °C. For under floor heating
applications, the temperature range can be set between 30-45
°C.
11.3.4- Summer Mode:
If the boiler in the OFF position is set to the summer position, the boiler will only
respond to the domestic hot water demands. In summer mode, the tap symbol appears fixed on the LCD
screen, the radiator icon does not appear. When the domestic hot water is heating request, the tap symbol
flashes (1 time/sec). In this mode, the domestic hot water temperature can be adjusted between 30-
65 °C.
11.3.5- Comfort Mode:
The standard operating mode of the boiler is Comfort mode. By pressing the
"Reset" button, Eco-Comfort modes can be switched. When Comfort mode is active, "Comfort" icon is
displayed on the LCD screen. Comfort mode is only for radiator heating circuit. It has no effect on use of
domestic water circuit. In this mode, the boiler responds to fast heating demands by running in modulation.
11.3.6- ECO Mode:
By pressing the "Reset" button, Eco-Comfort modes can be switched. When Eco
mode is active, "Eco" icon is displayed on the LCD screen. Eco mode is only for radiator heating circuit. It
has no effect on use of domestic water circuit. This mode allows savings on fuel by performing on-off
operation.