background image

 

7

N

0 1

N

P

P

P

P

0

1

 
 

 

By SMS Command  

You can 

Cancel

 or 

Activate

 the SMS service by sending SMS command to the unit as follows:  

To cancel; send SMS  

 

To Activate; send SMS  

 

 PPPP represent the four digit password.  
The unit will reply by SMS as follows:  

SMS service was canceled

” or “

SMS service was activated

”  

 

4.   How to select the Relay for the PUSH BUTTON input.  

The 

Push Button Input

 can activate Relay-1 or Relay-2 OR BOTH according to the function that was chosen for the 

relay.

 

The factory default setting for the Push Button Input is to activate RELAY-1 according to the function chosen.  

(The factory default is a 4 second PULSE). You can change this setting via the keypad or by SMS command. 

 

You can choose which RELAY the PUSH BUTTON INPUT activates by using the keypad, as follows: 
1. Enter program mode. 
2. Use the following format to make your selection  

 The letter “ N “ represents the numbers 1or 2 for Relay-1 or Relay-2 or the number 3 to activate both relays.  

   
 BY SMS command:   

 
 The unit will reply by SMS message to the sender accordingly to the command send, to confirm or to say failed.  

                  

 

5. How to choose the Relays’ function 

 For each one of the relays 1 and 2 you can choose one of the following two functions;  
 MOMENTARY (PULSE) or LATCH function.  
The factory default setting for both the relays is a MOMENTARY function (with a 4 second PULSE time). 

 
You can change this setting via the keypad as follows: 

In program mode you can select and choose the relay’s function as follows: 

 

The letter “ N “ represent the Number 1 or 2 for Relay-1 or Relay-2. 
The letter “ F “ represent FUNCTION,  1 for Momentary or 2 for Latch. 

 

BY SMS command:   

 

The system will send a confirmation SMS message to the sender that says: 
PPPP**02*NF#  CONFIRMED  or  PPPP*02NF#  FAILED 

 
 
 
 
 
 
 
 
 
 
 
 

F

N

 

P

 

P

P

 

P

 

0

2

Содержание MCI-3000V4

Страница 1: ...tem the system will then announce Your call was not answered please try later If the call was answered by any of the phone numbers then the owner of the unit can talk with the visitor and press the ha...

Страница 2: ...s related to the front keypad access control system The relay 1 connections COM1 N O 1 can be used to activate the electric latch of the pedestrian gate and relay 2 connections COM2 N O 2 can be used...

Страница 3: ...nection Diagram E5366 All Rights Reserved to ECA Electronic Engineering Pty LTD Tel 61 3 95720535 Email ecaelcetronic bigpond com Factory No 76 80 Levanswell Rd Moorabbin Vic 3189 Australia www gateso...

Страница 4: ...r phones by calling the SIM card of the unit with no cost of a call 1 Programming the phone numbers for each unit into the intercom system The following letters and configuration represent the program...

Страница 5: ...nt the number of Rings from 1 to 9 rings that the unit will wait for an answer before it will hang up and dial the next phone number in the memory 2 Deleting users phone numbers in the system You can...

Страница 6: ...by the symbol How to Delete ALL the users phone numbers You can delete all the users phone numbers via the keypad ONLY and not by SMS command as follows 1 Enter program mode 2 Press and then press and...

Страница 7: ...follows 1 Enter program mode 2 Use the following format to make your selection The letter N represents the numbers 1or 2 for Relay 1 or Relay 2 or the number 3 to activate both relays BY SMS command T...

Страница 8: ...stem will confirm the chosen interval time by a Beep sound as long as the chosen Time i e if the time selected was 7 seconds then the buzzer will sound for 7 seconds long Beep Setting the timers BY SM...

Страница 9: ...he SMS replay from the system i Confirming relay1 and relay 2 are No Longer Hold Active 8 How to limit the Talking Time In program mode you can select and limit the talking time of the visitor The fac...

Страница 10: ...ement END OF CALL By SMS Command To change the talking time by SMS command send the SMS as follows The unit will confirm by SMS message to the sender as follows Confirming the talking time was changed...

Страница 11: ...announce the level by a number from 0 to 5 according to the table below Zero No Reception One Bad reception Two Poor Reception Three Good reception Four Very Good reception Five Excelant Reception By...

Страница 12: ...command Via the keypad a Enter program mode b The following letters and configuration represent the sequence for programming the pin code numbers The first three digits U U U represent the user numbe...

Страница 13: ...to and then the star key followed by hash In this case the system will announce The pin code was deleted The following example shows how the pin code of the 875th user in system was deleted for relay...

Страница 14: ...y keypad Enter 00 and press and hold the key for 3 seconds till you hear a long beep Enter 00 once again within 10 seconds and the unit will respond with a long beep and announce Delete after 10 secon...

Отзывы: