Choosing Single or Double swing gates in the control panel
This control panel can be used for one single swing gate as well as for double swing gates.
In order to select and change the operation to be for a single gate, do as follows:
1.
Remove the Jumper “FUNCTION” in the control panel.
2.
Press and release button ( I ) on the remote control and the light relay will “Click” once.
3.
Return the Jumper into its place. End.
4.
For changing the setting back to dabble swing gate operation repeat step 1 to 3 and the
control panel will confirm that by two “Click” sounds in the light relay.
How to Cancel the opening time delay between the gates
The control panel sets two seconds
opening time delay
between the Master (M1) and the Slave gate
(M2) automatically. However, you can cancel this “opening time-delay” so that both the gates will open
and close simultaneously. For selecting
with or without
“opening time delay”
do as follows
:
1.
Remove the jumper “TIMER”
2.
Press and release the button ( III ) on the remote control. A double “click” by the light relay will
confirm cancellation of the time delay, i.e. both gates will always open and close simultaneously.
3.
Put Jumper Timer back into its place.
4.
To change back the setting to be with two seconds time delay; repeat the above procedure and this
time three “click” sounds will be heard to confirm and indicate this selection.
Setting the opening and closing TIMERS and the delay TIME between the gates
There are 5 timers in the control panel that need to be set according to the working time of each
motor. For each motor there are two timers that are needed to be set. The first timer called (T1) is
to be set for the period of time you would like Motor-1 to go fast, and the second timer (T2) is the
period of time you would like Motor-2 to go slow.
The third timer (T3) is to be set for the period of time you would like Motor-2 to go fast, and the
forth timer (T4) is the period of time you would like Motor-2 to go slow.
In addition to the above four timers, there is another timer (T5) which is for setting the
time delay
between the two gates while they close. Motor-2 (gate No. 2) closes first and after a few seconds
(set by timer T5) Motor-1 (gate NO. 1) will close behind it. See diagram as followed.
T
1
T
2
T
3
T
4
T
5
M o to r 1
M o to r 2
S e ttin g tim e r s fo r o p e n in g
S e ttin g tim e d e la y fo r c lo s u r e
F
A
S
T
F
A
S
T
S L O W
S L O W
M o to r 2
M o to r 1
M o to r-2 w ill c lo s e firs t,
a n d a fte r a p re s e t tim e o f tim e r T
5