background image

 

2. HOW TO DELETE ALL THE REMOTE CONTROLS FROM THE CONTROL PANEL’ S MEMORY. 

1.

 

Remove the jumper “REMOTE” in the CP.  

2.

 

Disconnect the power to the unit. 

3.

 

Wait 5 seconds and reconnect the power to the unit. 

4.

 

Return the jumper “REMOTE” into its place. All the remote controls are deleted. 

   

 

 

OPERATION PROGRAMS; Step By Step / Automatic Closure 

 

1.   

HOW TO CHOOSE THE REQUIRED OPERATION PROGRAM to open and close the gate. 

     The control panel allows you to choose one out of two following operation programs:  

 

Program (I) : Semi automatic – Step By Step  

When using this type of operation, the unit will open, close or stop the gate by the command of the remote 
control or the manual push button only (if connected). The first command opens the gate, the second stops, 
the third closes the gate, and the fourth stops the operation and so on.  

 
Program (II) : Automatic operation 

This program to be used for auto-close operation. When pressing the remote control, the CP will open the 
gate and keep the gate open for a preset time, after which the CP will close the gate automatically. 

 

2.   HOW TO SELECT THE REQUIRED OPERATION PROGRAM. 

Remove the “PROGRAM” Jumper in the control panel, choose and press button I or II on the remote 
control according to required program you need and return the jumper to its place.  

 

 

How to Adjust the Motor’s Power      

  

The motors’ force can be adjusted 

by the remote control

 to one out of the ten different levels as follows: 

1.

 

Remove Jumper “POWER” in the CP. 

2.

 

Press and release button ( I ) on the remote control for 

Max Force

 or Press button ( II ) for a  

Minimum Force 

of  about 50%. 

     Three “Click” sounds in the light relay will indicate the selection of Max. level of  Force and two 
      “Click” sounds will confirm Min. level of force selection.  
3.

 

You can adjust and reduce the force by one step to a lower level, by pressing button (III) once, 
or to increase the force by one level higher by pressing and releasing button (IV) once.  

      A “Click” sound will follow to confirm each decrease and increase of level selection.  
4.  Return Jumper POWER to its place after selecting the force level required.    
 

LEVEL  

10 

POWER  

100% 

95% 

90% 

85% 

80% 

75% 

70% 

60%  65% 

50% 

Remote’s  
Button 

Press 

( I )

   

 

 Increase power press ( III )   <=

  To  

=>  Reduce power press   ( IV )

   

Press 

( II )

  

 

 

 

 

Setting the Timer for Automatic closure  

 

The control panel has a 

programmable

 timer that can be set to close the gate automatically after each time 

it opens in automatic mode, and it can be as follows:   

1.

 

Remove the jumper “TIMER” in the CP.  

2.

 

Press and release button (II) on the unit’s remote control and the light relay will start to flash.  

3.

 

Wait the period of time you wish to set the Auto Close Time (for example 15 seconds) and then press 
and release button (II) of the remote control once again. 

4.

 

A “Click” sound will indicate that the auto close delay time has been set for the automatic operation.   

5.

 

Return the Jumper “TIMER” into its place.  

 

 

Отзывы: