background image

DIGIITAL COMPUTERIZED CONTROL PANEL for 240V ac SWING GATE MOTORS    

Model: DCP-242V2 

The DCP-242V2 is a universal 

C

ontrol 

P

anel (

CP

) that can replace any 240V AC control panel for swing gates. It is very simple to 

set the timers 

remotely

 and to choose the required operating program. The CP has a built-in learning type radio receiver that enables 

the end user to teach the CP additional remote controls wirelessly, without the need of accessing the control panel. 
Its sensitive rolling code receiver enables to operate the CP with a four-channel (TR-4RS) remote control from a distance of 200m’. 
The DCP-242V2 has two options of operating programs from which the user can choose; 

Automatic

 or 

Step By Step

.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
   

 

 
 

 

 
 
 
 
 
 
 

 
 
Input Terminals: 

No.1

:  

 + 24V/AC / 60mA; power supply for photo sensor only.  

 

No.2:    - 24V/AC  

       

No.3:   Common output.  
No.4:   Common output.  
No.5:   Optic Sensor Input: Should be connected to Common contacts of an optic sensor.  
No.6:   PB1; Push Button input for manual operation.  
No.7:   PB2; Push Button input for pedestrian mode, manual operation.  

No.  8: Com.  
No.  9: STOP              Optional inputs for Access Control Systems  
No.10: CLOSE           supplied upon request.     
No.11: OPEN  

No 12: contact of the relay output for electric lock or warning light. 
No.13: contact of the relay output for electric lock or warning light. 

 
240V AC Power Input: 

Terminal No. 

19: 

 Should be connected to neutrals 240VAC.   

Terminal No. 

20: 

 Should be connected to the live voltage; 240V AC 50Hz. 

 

Electrical specifications: 

 Operating voltage: 240V/AC 50Hz.             Output load:  Max. 1.5Hp 240v/AC. 

  Main Fuse           : 5A max / 240V AC.       24V Ac Fuse: 0.5A / 24V AC.     
 

SW-240 INSTRUCTIONS 

22

21

20

19

18

9

8

7

6

FORCE

240V AC

4A FUSE

Neutral  - Input

220V live - Input

PROGRAM

REMOTE

Jumpers

Power Indicator

LED

NEUTRAL

LIVE - close

LIVE - open

17

16

AC MOTOR

1

23

AC MOTOR

2

FUNCTION

TIMER

5

4

3

2

11

10

1

24

25

2

4

V

 A

C

 *

Com.

STOP

Pedestrian

Com.

OPEN

CLOSE

Photo Sensor LED

N.O.

N.C.

NEUTRAL

LIVE - close

LIVE - open

* This 24V output should NOT be used for an electric lock

Digital Control Panel

240V AC Swing Gates

Model : DCP 242

ECA Electronic Engineering Pty, LTD.

Australia TEL: 03-95 72 0535

www.gatesonsolar.com

Com.

O/S/C

13

12

L

ig

h

t

R

e

la

y

/ L

o

c

k

N.O.

BP2

BP1

N.O.

N.O.

Remove bridge when

photo sensor is in use

24V / 0.5A

 FUSE

-

+

N
C

N
O

C
M

Photo

Sensor

Rx

1   2   3   4    5

-

+

Photo

Sensor

Tx

1    2

Capacitor for M1

Capacitor for M2

14

15

Photo Sensor Input

Push buttons LEDs

Transf.

Elc. Lock

12V AC

240V AC

Optional inputs

upon request

Отзывы: