9.3- Electrical Connection
Electrical installation must be made according to the national and local instructions. The boiler must be
earthed and a standard 230 V AC – 50 Hz supply is required.
CAUTION:
Disconnect power supply to prevent electrical shock before
connecting the electrical supply.
CAUTION:
If the supply cord is damaged, it must be replaced by the
manufacture, its service agent or similarly qualified person in order to avoid a hazard.
CAUTION:
The 2-amp bipolar fuse with a minimum contact opening of 3 mm must be
used in the electrical connection of the boiler.
CAUTION:
The cable diameter (including insulation) of the electrical installation to be
installed must be at least 14 mm and the pipe diameter used must be at least 16 mm.