33
1- Press reset bu
�o
n.
2- If the err
o
r is s
�
ll present (
o
r persists) a
�
er
reset, n
o�
fy auth
o
rized service
o
f E.C.A.
F07
Over Temperature Err
o
r f
o
r
Flue Gas
It
o
ccurs when the temperature
o
f
the
fl
ue gas exceeds 95
o
C.
1- N
o�
fy auth
o
rized service
o
f E.C.A.
1- Check water pressure in heater installa
�o
n
o
f y
o
ur device.
2- Fill the system with water un
�
l the pressure
reaches 1.5-2 bar (device will eliminate err
o
r
when the pressure is
o
ver 0,8 bar).
3-Check y
o
ur valves and installa
�o
n against
leaks.
4- If the pr
o
blem is s
�
ll present (
o
r persists),
n
o�
fy auth
o
rized service
o
f E.C.A.
1- Press reset bu
�o
n.
2- If the err
o
r is s
�
ll present (
o
r persists) a
�
er
reset, n
o�
fy auth
o
rized service
o
f E.C.A.
1- Check water pressure in heater installa
�o
n
o
f y
o
ur device.
2- Tur
off
the device and restart it.
3- If the err
o
r is s
�
ll present (
o
r persists) a
�
er
reset, n
o�
fy auth
o
rized service
o
f E.C.A.
1- Press reset bu
�o
n.
2- If the err
o
r is s
�
ll present (
o
r persists) a
�
er
reset, n
o�
fy auth
o
rized service
o
f E.C.A.
F47
Water Pressure Sens
o
r Err
o
r
Water pressure sens
o
r is n
o
t
plugged in
o
r there is n
o
c
o
ntact.
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F42
Water Fillin (Aut
o
) N
o
t
C
o
mpleted
Water
fi
lling valve may be failed
o
r
mains water pressure may be
insu
ffi
cient.
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F43
L
o
w Water Pressure A
�
er Aut
o
Water Filling Fault
Water
fi
lling valve may be failed
o
r
mains water pressure may be
insu
ffi
cient.
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F40
High Water Pressure Fault
It
o
ccurs when water pressure
sens
o
r detects a rela
�
vely high
water pressure (2,9 bar) f
o
r y
o
ur
device.
F41
Water Filling (Aut
o
) Running
Aut
o
ma
�
c water willing is
c
o
n
�
nuing
F37
L
o
w Water Pressure Fault
It
o
ccurs when water pressure
sens
o
r detects a rela
�
vely l
o
w
water pressure (0.4 bar) f
o
r y
o
ur
device.
F39
Outd
oo
r Temperature Sens
o
r
Fault
Outd
oo
r temperature sens
o
r
might be defec
�
ve.
F34
L
o
w Supply v
o
ltage
It
o
ccurs when the supply v
o
ltage
falls bel
o
w 170V.
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F36
Main Frequency Fault
Main (electricity) pr
o
blem
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F10
Insu
ffi
cient water circula
�o
n
err
o
r
Cl
o
gging in installa
�o
n
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F13
Repeated Reset Fault
Pressing
o
f Reset bu
�o
n m
o
re
than 5
�
mes in an h
o
ur
1- N
o�
fy auth
o
rized service
o
f E.C.A.
F05
Fan Feedback Fault
Failure
o
f fan
o
r fan cable
Содержание CONFEO PREMIX P Series
Страница 2: ......
Страница 13: ...13 5 5 Electrical Diagram...
Страница 16: ...16 Figure 6 7 3 Distances for Placement of Flues Figure 7...
Страница 37: ...37 15 INSTALLATION TEMPLATE 15 1 HM Model...
Страница 38: ...38 15 2 HCH Model...
Страница 39: ...39 15 3 HST Model...
Страница 43: ......
Страница 45: ......
Страница 46: ......