Serial baud rate
115200
Serial port parameters 8 / None / 1
2.3.3.Data transmission test
After the above operation steps, follow the factory default parameters of the equipment
and perform the following operations to realize the transparent data transmission test.
The operation steps are as follows:
(
1
)
Open the test TCP/IP debugging assistant software;
(
2
)
Select TCP Client mode in the "network setting area". The remote host address
corresponds to (default local IP of the device: 192.168.3.7). The remote host port
corresponds to the factory local port 8887 of the device. Click Connect;
(
3
)
Wait for the computer to connect to the serial server. After the connection is
completed, the LINK light of the serial server is always on;
(
4
)
Open the serial port assistant, set the serial port baud rate to 115200, set the
serial port parameter to 1/8/None, and click to open the serial port;