Chengdu Ebyte Electronic Technology Co.,Ltd.
E95M-DTU(400SLxx-xxx) User Manual
Copyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.
25
Frequency channel: 0~83
network ID:0~255
Key: 0~65535
When using the upper computer to configure the relay mode, users need to pay special attention to it. In the upper computer, the
parameters are decimal display mode, so the radio address and network ID need to be converted into binary. If the network ID
input by the transmitter A is 02 and the network ID input by the receiver B is 10, then the relay terminal R sets the station address,
then the hex value 0X020A is converted to the decimal value 522 as the radio address filled by the relay end R. That is, the radio
address value of the relay terminal R that needs to be filled in is 522.
9. Program the radio stations
work pattern
M1
M0
explanatory note
Configuration
mode
The indicator
light is bright
The indicator
lights go out
Stations can only be programmed by using the configuration
software in the current mode
1
、
Programming can only be performed in specific working mode (see table above). Please sure the radio working mode is
correct.
2
、
Relevant parameters can be modified by opening the E95M-DTU (400 SLxx-xxx) configuration software without complex
programming.