background image

Chengdu Ebyte Electronic Technology Co.,Ltd.

E95M-DTU(400SLxx-xxx) User Manual

Copyright ©2012–2023, Chengdu Ebyte Electronic Technology Co.,Ltd.

17

Example 2: simultaneously configure the module address (0x1234), network address (0x00), serial

port (9600 8N1), empty speed (2.4K)

Send to: C2 00 04 12 34 00 60

Return: C1 00 04 12 34 00 60

4

Wireless

configuration

Instruction: CF CF + General instruction

Response: CF CF + conventional response

Example 1: The wireless configuration channel is 0x09

Wireless command header command starting address length parameter

Send to: CF CF C0 05 01 09

Return: CF CF C1 05 01 09

Example 2: wireless simultaneous configuration module address (0x1234), network address

(0x00), serial port (9600 8N1), and airspeed (2.4K)

Send to: CF CF C0 00 04 12 34 00 60

Return: CF CF C1 00 04 12 34 00 60

5

format error

Format error response

FF FF FF / “=ERR ”

5.2 Register description

order

number

read-w

rite

name

description

remarks

00H

Read /

write

ADDH

ADDH (default 0)

Module address of high and low bytes;
Note: When the module address is equal to FFFF,
it can be used as a broadcast and listening address,
that is, the module will not filter the address

01H

Read /

write

ADDL

ADDL (default 0)

02H

Read /

write

NETID

NETID (default 0)

Network address, used to distinguish networks;

When communicating with each other, set it as the
same.

03H

Read /

write

REG0

7

6

5

UART Serial Rate (bps)

The two modules of mutual communication, the

serial port port rate can be different, the

calibration mode can also be different;

When large data packets are launched

continuously, users need to consider the data

blocking caused by the same port rate, or may

even be lost;

It is generally recommended that the same have

the same the same.

0

0

0

The serial port port rate is 1200

0

0

1

The serial port port rate is 2400

0

1

0

The serial port port rate is 4800

0

1

1

Serial port port rate of 9600
(default)

1

0

0

The serial port port rate is
19200

1

0

1

The serial port port rate is
38400

1

1

0

The serial port port rate is
57600

1

1

1

The serial port port rate is
115200

4

3

Serial check bit

The communication two sides serial port mode
can be different;

0

0

8N1 (by default)

0

1

8O1

1

0

8E1

1

1

8N1 (equivalent to 00)

Содержание E95M-DTU

Страница 1: ...1 E95M DTU 400SLxx xxx...

Страница 2: ...xplanation 14 3 1 Fixed point launch 162 m 14 3 2 Broadcast transmission 16 approx 14 3 3 Broadcast address 14 3 4 Listen address 14 4 work pattern 15 4 1 Transmission mode mode 0 15 4 2 WOR Mode Mode...

Страница 3: ...production use modification or disclosure to third parties of this document or any part thereof without the express permission of EBYTE is strictly prohibited The information contained herein is provi...

Страница 4: ...are is more convenient Support AT instruction it is more convenient to use Ultra small volume size of 80 28 27mm easy and quick installation E95M DTU 400SL22 xxx is up to 5 Km under ideal conditions E...

Страница 5: ...reliability of the station Communication ports and power supply interfaces shall be isolated with high protection Powerful software functions all parameters can be programmed by setting such as power...

Страница 6: ...ough the Mode button control Press the Mode button once for about 1ms to switch the mode once Details of the mode switching are shown in the following table No Class M1 M0 Note pattern 0 Through trans...

Страница 7: ...sh light is red when sending data and green when receiving data 3 MO Mode indicator light Operating mode indicator light 4 M1 Mode indicator light Operating mode indicator light 5 Mode Mode switch but...

Страница 8: ...r light Operating mode indicator light 5 Mode Mode switch button Working mode switching control 6 G Signal ground Anti interference grounding 7 T The RS232 bus TX interface RS232 interface The TX inte...

Страница 9: ...or light Operating mode indicator light 5 Mode Mode switch button Working mode switching control 6 G Signal ground Anti interference grounding 7 T The TTL bus TX interface RS232 interface The TX inter...

Страница 10: ...Chengdu Ebyte Electronic Technology Co Ltd E95M DTU 400SLxx xxx User Manual Copyright 2012 2023 Chengdu Ebyte Electronic Technology Co Ltd 10 1 5 Installation dimensions...

Страница 11: ...eration of LoRa frequency expansion DC power supply Suitable for distant vulnerable environments E95M DTU 400SL 30 232 410 125 493 125 30 10 New generation of LoRa frequency expansion DC power supply...

Страница 12: ...range is from 1200 to 115200 7 address code Factory default 0 A total of 65 536 address codes can be set 2 3 Frequency range and channel number Model Frequency Transmitting power Reference distance Sp...

Страница 13: ...12V 24V E95M DTU 400SL 22 xxx 45 26 10 7 E95M DTU 400SL 30 xxx 250 125 9 5 Note It is recommended to retain more than 50 of the current margin when selecting the power supply which is conducive to the...

Страница 14: ...m 3 2 Broadcast transmission 16 approx 3 3 Broadcast address Example Set the station A address to 0xFFFF and the channel to 0x04 When station A is used as transmission the same mode transparent trans...

Страница 15: ...eiver support aerial wake up pattern 2 Configuration mode light on light goes out The user accthe register through the serial port to control the working status of the station The user can configure t...

Страница 16: ...esponse C1 starting address length parameter Example 1 The configuration channel is 0x09 Command start address length parameter Send to C0 05 01 09 Return C1 05 01 09 Example 2 simultaneously configur...

Страница 17: ...ow bytes Note When the module address is equal to FFFF it can be used as a broadcast and listening address that is the module will not filter the address 01H Read write ADDL ADDL default 0 02H Read wr...

Страница 18: ...sion mode Register 0x00 current ambient noise RSSI Register 0X01 RSSI last received The current channel noise is dBm 256 RSSI Instruction format C0 C1 C2 C3 starting address read length Return C1 addr...

Страница 19: ...seconds reaching two seconds 0 Disable default 1 start using 3 The WOR mode transceiver control Only valid for mode 1 1 In the receiving mode of word the module can modify the delay time after wake up...

Страница 20: ...T HELP Query to the AT instruction set supported by the module the AT instruction adopts the port rate of 9600 8N0 When the input parameter exceeds the range it will be limited Please do not let the p...

Страница 21: ...DR 1234 Set the module address to 1234 AT CHANNEL channel Set up the module working channel AT CHANNEL 23 Set the frequency to 433 125M AT NETID netid Set the network ID AT NETID 2 Set the network ID...

Страница 22: ...frequency is set at 433 125M AT NETID Query network ID AT NETID 2 The return network ID is 2 AT KEY Query module key Read is not supported security considerations return ERR AT DELAY Query WOR delay...

Страница 23: ...gram will automatically exit otherwise even if the restart it will enter the upgrade mode indefinitely After entering the upgrade mode the port rate will automatically switch to 115200 until you autom...

Страница 24: ...nd node 3 has different addresses from node 1 so it does not output data bi directional relay As configured data nodes 2 and 4 sent by nodes 1 may be received and data sent by nodes 2 and 4 can also b...

Страница 25: ...n the relay terminal R sets the station address then the hex value 0X020A is converted to the decimal value 522 as the radio address filled by the relay end R That is the radio address value of the re...

Страница 26: ...232 410 125 493 125 22 5 New generation LoRa guide rail type RS232 E90 DTU S L system type communication DC power supply E95 DTU 400SL 30 485 RS485 410 125 493 125 30 10 New generation LoRa guide rail...

Страница 27: ...DTU 400SL 30 485 RS485 410 125 493 125 30 10 New generation of LoRa guide rail type RS485 E90 DTU S L system class communication AC power supply E96 DTU 400SL 30 232 RS232 410 125 493 125 30 10 New g...

Страница 28: ...ay burn the transmitter 5 The ground wire of digital transmission station should be well connected with the ground wire of external equipment such as PC PLC etc and the ground wire of power supply oth...

Страница 29: ...ts in this manual 2 Due to the continuous improvement of the hardware and software of the product this specification may be changed without further notice and the latest version shall prevail Revise t...

Отзывы: