Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT11 User Manual
Copyright ©2012–2020
,
Chengdu Ebyte Electronic Technology Co.,Ltd
19
5.4.1.16 Restart the device
Operation
code
Parameter
Request
0x14
N/A
Response
0x14
Returns the operating state value
For example,
Request
02 C0 14
Response
03 43 14 00
Remark
Restarting the device requires at least 1S to complete.
5.4.1.17 Restore Factory
Operation
code
Parameter
Request
0x15
N/A
Response
0x15
N/A
For example,
Request
02 C0 15
Response
03 43 15 00
Remark
1. Restore factory to clear all parameters;
2. Restore the factory module and restart after 1S.
5.4.1.18 Get the software version number
Operation
code
Parameter
Request
0x16
N/A
Response
0x16
High version
(
1byte
)
Low version
(
1byte
)
01
00
For example,
Request
02 C0 16
Response
04 40 16 01 00
Remark
5.4.1.19 Sleep configuration
This function is used to set how many seconds the UART does not receive and then enters sleep mode.
Operation code
Parameter (1 byte)
Request
0x17
time
(
s
)
Response
0x17
time
(
s
)
For example,
Request
03 C0 17 05
Response
03 40 17 05
Remark
1. Parameter unit S, range 0X01-0XFF, parameter 00 means do not enter sleep;