Chengdu Ebyte Electronic Technology Co., Ltd
E104-BT11 User Manual
Copyright ©2012–2020
,
Chengdu Ebyte Electronic Technology Co.,Ltd
20
2. Effective immediately, save after power off.
5.4.1.20 Sleep Inquiry
Operation
code
Parameter
Request
0x18
N/A
Response
0x18
E104-BT10-N whether to enter sleep and to enter sleep overtime
For example,
Request
02 C0 18
Response
03 40 18 05
Remark
5.4.1.21 UART data bit configuration
Operation
code
Parameter (1 byte)
Request
0x19
0
Unavailable
1
Unavailable
2
Unavailable
3
Unavailable
4
8 data bits
5
9 data bits
Response
0x19
Same as request
For example,
Request
03 C0 19 04
Response
03 40 19 04
Remark
1. Set unsupported data, the module responds to an error message
2. Restart takes effect, save after power off
5.4.1.22 UART data bit acquisition
Operation
code
Parameter (1 byte)
Request
0x1A
N/A
Response
0x1A
Same as request
For example,
Request
02 C0 1A
Response
03 40 1A 04
Remark
5.4.1.23 UART stop bit configuration
Operation
Parameter (1 byte)
Содержание E104-BT11