background image

Chengdu Ebyte Electronic Technology Co., Ltd

E104-BT10-IPX User Manual

Copyright ©2012–2019

C

hengdu Ebyte Electronic Technology Co., Ltd

4-17

code

Request

0x09

/

Respond

0x09

Return MAC of networking device and assigned unicast

address and element numbers

For

example

Request

02 C0 09

Respond

0B 40 09 112233445566 0004 03

Notes

1

Suitable for E104-BT10G-IPX

2

Return MAC of networking device and assigned unicast address and element

numbers

11.Baud rate configuration

Operation code

Parameter

Request

0x0E

Baud rate serial number to be configured

range:

0x00~0x07

Respond

0x0E

Return the current baud rate serial number

For

example

Command

Baud rate serial number notes

03 C0 0E xx

Xx is baud rate serial number to be configured

0x00~0x07

00

230400

01

128000

02

115200

03

76800

04

57600

05

19200

06

9600

07

4800

Notes

1

Suitable for E104-BT10G-IPX and E104-BT10N-IPX

2

For example 3 C0 0E 02

when succeed, return 03 40 0E 02, if exceed range, return

03 40 0E FF

12. To read baud rate

Operation code

Parameter

Request

0x0F

/

Respond

0x0F

Return the current baud rate serial number

For

example

Command

Return

Notes

02 C0 0F

03 40 0F xx

Xx is baud rate number
00

230400

01

128000

Содержание E104-BT10-IPX

Страница 1: ...E104 BT10 IPX User Manual TLSR8269F512 UART SMD SIG Mesh Module...

Страница 2: ...pecific instruction 11 4 2 1 Networking introduction 11 4 2 2 Node networking process and status indication 11 4 2 3 Networking whitelist 12 4 2 4 Network exception and processing 13 4 2 5 Remove node...

Страница 3: ...Chengdu Ebyte Electronic Technology Co Ltd E104 BT10 IPX User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 2 About us 29...

Страница 4: ...nforms to sig standard HSL H Hue S Saturation L lightness model one click implementation of the lighting control application scenario Ideal for IoT information collection large scale networking commun...

Страница 5: ...V 1 9 3 3 3 6 3 3 V ensures output power Communication level V 3 3 For 5V TTL it may be at risk of burning down Operating temperature 40 80 Frequency MHz 2400 2483 5 ISM band Power consumption Transm...

Страница 6: ...onnecting to power source reference ground 2 PE0 PWM output Corresponds to green indicator of SIGMESH HSL 3 PE1 PWM output Corresponds to red indicator of SIGMESH HSL 4 DM GPIO 5 DP GPIO 6 PA0 GPIO 7...

Страница 7: ...away as possible from the power supply transformers high frequency wiring and other parts with large electromagnetic interference High frequency digital routing high frequency analog routing and powe...

Страница 8: ...E104 BT10 IPX User Manual Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 4 7 3 2 Circuit Diagram As shown to connect VCC GND TX RX then communication test can be conducted 4 Function i...

Страница 9: ...ot directly send data to the C module If module B is placed between the A module and the C module then the data will be repeatered by B and then received by C Module A needs to send data to the entire...

Страница 10: ...ls from Mesh Profile3 86 4 1 3 Device role In SIG MESH protocol roles include node low power node relay node friend node proxy node Related functions are as explained below Node An edge node in the en...

Страница 11: ...on applies to the fact that two nodes send and receive messages to each other but without relay capability data packets cannot be forwarded 2 ADV Lower power That is a low power broadcast connection U...

Страница 12: ...ce during the provisioning process In the same mesh network each node device may have multiple addresses However a model in each device can only have one address but different models can be bound to o...

Страница 13: ...p 3 Assign Netkey The timeout period for assigning netkey is 10 seconds If netkey is successfully assigned within 10 seconds go to step 4 Otherwise the indicator will go out The serial port will retur...

Страница 14: ...ent network and it returns If it is not deleted it is not returned See the manual 3 2 SIG message for instructions and usage details 4 3 Data format All data exchanged by the serial port including par...

Страница 15: ...d 16 bytes of NetKey data For example Request 12 C0 00 11223344556677889900112233445566 Respond 12 40 00 11223344556677889900112233445566 Notes 1 suitable for E104 BT10G IPX 2 After configuration the...

Страница 16: ...This is for reading configured AppKey 5 Networking address configuration Operation code Parameter Request 0x04 Configure the unicast address for networking next time 2 bytes Respond 0x04 Return the c...

Страница 17: ...d MAC 8 To delete networking filter Operation code Parameter Request 0x07 Serial number to be deleted 1 byte Respond 0x07 Serial number MAC address of deleted device For example Request 03 C0 07 00 Re...

Страница 18: ...eter Request 0x0E Baud rate serial number to be configured range 0x00 0x07 Respond 0x0E Return the current baud rate serial number For example Command Baud rate serial number notes 03 C0 0E xx Xx is b...

Страница 19: ...e configured range 0x00 0x0A Respond 0x12 Return configured power number For example Command Notes 03 C0 12 xx Xx is baud rate serial number to be configured 0x00 0x0A 00 8dBm 01 4dBm 02 0dBm 03 4dBm...

Страница 20: ...Return current MAC address of device For example Request 02 C0 01 Respond 08 40 F0 112233445566 Notes 1 Suitable for E104 BT10G IPX and E104 BT10N IPX 16 To restart device Operation code Parameter Req...

Страница 21: ...s of current device Operation code Parameter Request 0x0B Respond 0x0B Return main address of current E104 BT10N IPX device For example Request 02 C0 0B Respond 05 40 0B 01 0004 Notes 1 Suitable for E...

Страница 22: ...for details about SIG message SIG message follows format below Transmitting Command 1 byte Target address 2 byte Sig mesh message 0xC1 Main address of target device Request Receiving Command 1 byte T...

Страница 23: ...ta 0xC2 Main address of target device Valid data Receiving Command 1 byte Target address 2 byte Original address 2 byte Data 0x42 Main address of target device Main address of original device Valid da...

Страница 24: ...ebugging assistant to select the baud rate 115200bps 8 data bits no parity 1 stop bit select hexadecimal transmission The E104 BT10G IPX terminal edits and sends the Device Access command 02 C0 09 Whe...

Страница 25: ...on light generic onoff command see details from 3 2 see details from Mesh Model 3 2 1 2 Generic OnOff Set E104 BT10G IPX send comand to turn off light generic onoff command see details from 3 2 see d...

Страница 26: ...byte Electronic Technology Co Ltd 4 25 5 4Transparent transmission 5 4 1 Broadcast transmission Device 0001 broadcasts 11223344AA in hex format See 3 3 input target address as FFFF all device in the n...

Страница 27: ...al Copyright 2012 2019 Chengdu Ebyte Electronic Technology Co Ltd 4 26 5 4 2 Fixed point transmission For example Device 0001 sends 11223344AA in hex format to device 001 See details from 3 3 Transmit...

Страница 28: ...igh the higher the air data rate the shorter the distance When the power supply at room temperature is lower than the recommended low voltage the lower the voltage is the lower the transmitting power...

Страница 29: ...5 Ag3 Cu0 5 Preheat Temperature min Tsmin 100 150 Preheat temperature max Tsmax 150 200 Preheat Time Tsmin to Tsmax ts 60 120 sec 60 120 sec Average ramp up rate Tsmax to Tp 3 second max 3 second max...

Страница 30: ...terface Hz dBm m mm E104 BT10 TLSR8269F512 2 4G 8 50 19 13 SMD TTL Revision history Version Date Description Operator 1 0 2019 4 12 Initial Version 1 2 2019 11 11 Function update Ren About us Website...

Отзывы: