Terminal description
Terminal
Connection description
C, NC, NO
Relay outputs. Connection to external device that is to be
controlled by switches relay.
GND
Device ground, common for other input and output
IN1 - IN4
Signal inputs. Possible connection of detectors
contacts or alarm control panel outputs. GND terminal
is common for all inputs.
OUT1
Type OC output. It may control external device.
Provides ground during activation.
V+
Connect to the positive pole (+13,8V) of the power
supply.
GND
Connect to the negative pole of the power supply.
M
ANUFACTURER RESERVES THE RIGHT TO AMEND APPEARANCE OF PRINTED CIRCUIT
WITH NO EFFECT ON FUNCTIONALITY OF DEVICE
.
1.3.5.
Installation and wiring
All connections must be made with the power off.
Connections of wires shall be made with due care to prevent any faults or dead
shorts.
Wires should enter the enclosure using the installed cable glands.
The device is equipped with a built-in GSM antenna. In areas with poor GSM
signal it is possible to use an external GSM antenna. (Not included in the kit). In
order to wire the external antenna connector into the housing, remove one of the
cable glands and insert the supplied rubber grommet.
After checking all the connections, you can connect an external power supply.