CAUTION: The Limit Mode (See Programming 14, 15, 16, 17) functionality is still active even
while the display is in programming mode. Changing LIMITS may result in the Limit/Monitor
Signal hardware output becoming active immediately.
To exit programming mode,
press and hold
the MODE key and then
momentarily
press the 0
(zero) key.
The Display will automatically exit programming mode after 60 seconds of no key activity.
Programming Parameters are listed below. Values in [] are the available range of values that
can be programmed for that entry. Factory defaults are shown in bold.
Pr0 – Encoder Direction [0, 1]
Change value to reverse the direction of measurement readings.
Pr1 – Enable/Disable Segment Offset [0, 1]
0 = For ABSOLUTE scales shorter than 430mm, (16.9in). ALL
Incremental scales.
1 = for all ABSOLUTE scales longer than 430mm, (16.9in).
Pr2 – High Speed Read Head [0, 1]
0 = Normal Read Head.
1 = High Speed Read Head.
Use this setting
only
if instructed by special instructions included with
High Speed Read heads. A setting of 1 will impact battery life.
Pr3 – Enable/Disable the +, - and ZERO keys [0, 1]
0 = Disables operation of Zero, + and – keys (Display will be in Lock
Mode.)
1 = Enables operation of Zero, + and – keys.
Pr4 – Display Resolution [0, 1 or 2]
Sets the display resolution in
decimal
mode. (No change in fractions
Mode.)
0 = Reduced resolution Inch = xxx.xx MM = xx.x
1 = Normal resolution Inch = xxx.xxx MM = xx.xx
2 = Increased resolution Inch = xx.xxxx MM = xx.xx (Inch
mode only)
Auto scaling will allow measurements of over 100 inches when in
High
resolution.
Measurements over 100 inches will automatically be reduced to 3
Decimal
places.
REV A 12-2-05 20