![ebm-papst VTD-60 K5SB Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/ebm-papst/vtd-60-k5sb-series/vtd-60-k5sb-series_translation-of-the-original-operating-instructions_3793050034.webp)
34/37
Item no.: HAB 100177146 - 000 · EN · Change ·Release 2020-10-26
Control electronics
Control electronics
VTD-60.XX-K5SB
VTD-60.XX-K5SB
Maintenance & error handling
7 Maintenance & error handling
NOTICE
Do not perform any repairs on the control electronics. Send the control electronics to ebm-papst for repair or
replacement.
7.1 Cleaning
To ensure a long service life, check the control electronics regularly for proper operation and soiling. The frequency of checking
is to be adapted accordingly depending on the degree of soiling. When cleaning the control electronics, the following instructions
must be observed:
• Do not clean the control electronics using a water jet or high-pressure cleaner.
• Do not use acid, alkali, or solvent-based cleaning agents.
• Do not use any sharp-edged or pointed objects.
7.2 Safety checks
DANGER
Mechanical installation should be performed first before electrical hookup.
Danger to life due to electric shock when touching live parts
→
Only allow work to be carried out by a qualified electrician.
→
Make sure that the cables are de-energized.
→
Secure against renewed switch-on of the operating voltage.
→
Never work on live parts.
CAUTION
Hot surface – risk of scalding
→
Ensure sufficient protection against accidental contact.
→
Ensure there is sufficient cooling.
What is to be checked?
How to check
How often
Measure
Mounting the control electronics
Visual inspection
At least every
6 months
Mount
Check cables for damage
Visual inspection
At least every
6 months
Replace cables
Check control electronics for exter-
nal damage
Visual inspection
At least every
6 months
Replace control electronics
NOTICE
In the event of further malfunctions, please contact ebm-papst.
You should have the following information at the ready:
• Nameplate data
• Type and extent of malfunction
• Circumstances surrounding the malfunction
• Application data (cycle of torque, speed, loads, ambient conditions, etc.)
Do not operate the control electronics until the malfunction is conclusively resolved.