background image

G1G170-AB05-20

 

 
 
 
 

CAUTION

 

Operating instructions 

 
 
 

WARNING

 

In the event of failure, there is electric voltage at the

 

rotor and impeller

 

The rotor and impeller are base insulated. 

 Do not touch the rotor and impeller once they are installed. 

CAUTION

 

If control voltage is applied or a speed setpoint is stored,

 

the motor automatically restarts, e.g. after a power failure.

 

Danger of injury 

 Keep out of the danger zone of the device. 

 When working on the device, switch off the mains 

supply voltage and secure the latter from being switched on 

again. 

 Wait until the device stops. 

 After working on the device, remove any used tools or 

other objects from the device. 

1.5 Safety and protective functions

 

DANGER

 

Missing safety device and non-functioning safety device

 

If there is no safety device, you could be seriously injured, for 
example by reaching into the running device with your hands. 

 Operate the device only with a fixed and isolating safety 

protection and a fixed guard grille. The guard must withstand 
the kinetic energy of a fan blade detaching at maximum 

speed. 

 The device is a built-in component. You, the owner/ 

operator, are responsible for providing adequate protection for 

the device. 

 Instantly stop the device once you detect a missing or 

ineffective protective feature. 

1.6 Electromagnetic radiation

 

Interference from electromagnetic radiation is possible, e.g. in conjunction 
with open and closed-loop control devices. 
If unacceptable emission intensities occur when the fan is installed, 
appropriate shielding measures have to be taken by the user. 

NOTE

 

Electrical or electromagnetic interferences after

 

integrating the device in installations on the customer's

 

side.

 

 Verify that the entire setup is EMC compliant. 

1.7 Mechanical movement

 

DANGER

 

Danger of injury from open blower

 

Gas escapes. When the blower is open, you come into contact 
with rotating and electrically live parts. Escaping gas may also 
cause explosions. 

 Never open the blower. 

WARNING

 

Rotating device

 

Long hair, loose items of clothing and jewellery could become 
entangled and pulled into the device. You could be injured. 

Do not wear any loose clothing or jewellery while working 

on rotating parts. 

 Protect long hair by wearing a cap. 

Flying parts

 

Missing safety devices may cause fan blades to be ejected at 
high speeds, causing bodily harm. 

 Take appropriate safety measures. 

The safety devices must prevent contact with rotating parts 
and the printed circuit board. 

1.8 Deflagration

 

DANGER

 

Gas escapes through leaky housing after deflagration

 

Danger of injury 

 After a deflagration, check that the housing of the gas blower 

is tightly sealed. 

 Replace any gas blower with a leaky housing. 

DANGER

 

Fire and deflagration hazard

 

The gas blower is not approved according to Ex protection 
guidelines. Rotating parts can scrape against stationary parts. 
This may cause sparks and chips. The surface temperature 
may rise, resulting in a fire. 

 Check which hazards arise from installing, operating, 

servicing or disposing the gas blower in conjunction with 
your device. 
Prevent these hazards. 
Carry out all appropriate measures to this purpose. 

1.9 Emission

 

WARNING

 

Depending on the installation and operating conditions,

 

a sound pressure level greater than 70 dB(A) may arise.

 

Danger of noise-induced hearing loss 

 Take appropriate technical safety measures. 

 Protect operating personnel with appropriate safety 

equipment, e.g. hearing protection. 

 Also observe the requirements of local agencies. 

1.10 Hot surface

 

CAUTION

 

High temperature at the electronics enclosure

 

Danger of burn injuries 

 Ensure that sufficient protection against accidental contact is 

provided. 

1.11 Transport

 

NOTE

 

Transport of blower

 

 Transport the blower in its original packaging only. 

 Secure the blower so that it does not slip, e.g. by using a 

clamping strap. 

 
 

Item no.: 50103-5-9970 · Revision: 70943 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 2 / 12 

ebm-papst Mulfingen GmbH & Co. KG · Bachm

ь

hle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com 

T

ranslation of

 the 

or

iginal oper

ating instr

uctions

Содержание G1G170-AB05-20

Страница 1: ...rdous situations and important safety regulations DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Compliance with the measures is mandato...

Страница 2: ...r open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewel...

Страница 3: ...ith the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter Only using the device in stationary systems Installing the device into an overall system for moving a...

Страница 4: ...ating instructions Item no 50103 5 9970 Revision 70943 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 11...

Страница 5: ...male connector No 926 884 1 L N PE 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 Speed monitoring Not assigned PWM input Bleeder conne...

Страница 6: ...tomer specs cu customer unit Subject to alterations 3 3 Technical description Mass 4 35 kg Size 170 mm Surface of rotor Coated in black Material of protective Polyflam RPP 374 ND CS1 UL 97 V0 cover Ma...

Страница 7: ...ided Before working on the electrical connection the connections to the mains supply and PE must be shorted using an all pole disconnecting switch When working on the device you must switch off the sy...

Страница 8: ...on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assignment of your connector Connect the panel connector...

Страница 9: ...ing output connection monitoring circuit output 3 pulses per revolution current source 1 mA Not assigned PWM 2 6 kHz control input PWM on n 100 PWM low n 0 GND Connection for control interface Item no...

Страница 10: ...to the PWM control input if you are using the PWM control input Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 7 Switching off the device Switching off...

Страница 11: ...s supply voltage for a min of 25 s and switch it on again Ambient temperature Reduce the ambient too high temperature Reset by reducing control input to 0 Unacceptable Correct the operating operating...

Страница 12: ...pection At least every 6 months Visual inspection At least every 6 months Visual inspection At least every 6 months Repair or replacement of the device Replacement of the device Fasten Fasten Replace...

Страница 13: ...Translation of the original operating instructions...

Отзывы: