background image

G1G170-AB05-20

 

Operating instructions 

 
 
 

You can control the blower either via the 0-10 VDC input or the 
PWM input. Note: Inputs cannot be used simultaneously. 

 

3.2 Nominal data

 

 
 
 

3.4 Mounting data

 

For depth of screw, see chapter 3.1 Graphic rendition of products 

Secure the mounting screws against accidentally coming loose (e.g. 
by using self-locking screws). 

Motor

 

Phase

 

M1G074-CF 

1~ 

Strength class for

 

mounting screws

 

8.8 

Nominal voltage in VAC

 

115 

Frequency in Hz

 50/60 

Type of data definition

 fa 

You can obtain additional mounting data from the product drawing if 

necessary. 

3.5 Transport and storage conditions

 

Speed in min

-1

 

Power input in W

 

Current draw in A

 

Min. ambient

 

temperature in °C

 

Max. ambient

 

temperature in °C

 

Min. temp. of flow

 

medium in °C

 

Max. temp. of flow

 

medium in °C

 

5730 
345 
4.0 
- 25 
 
+ 55 
 
-25 
 
+80 

Use the device in accordance with its protection type. 

Max. permissible

 +80 

°C 

ambient motor temp.

 

(transp./ storage)

 

Min. permissible

 

-40 °C 

ambient motor temp.

 

(transp./storage)

 

3.6 Electromagnetic compatibility

 

EMC interference

 

Acc. to EN 61000-6-2 

ml = max. load · me = max. efficiency · fa = running at free air 
cs = customer specs · cu = customer unit 

Subject to alterations 

3.3 Technical description

 

Mass

 4.35 

kg 

Size

 170 

mm 

Surface of rotor

 

Coated in black 

Material of protective

 

Polyflam RPP 374-ND CS1 (UL 97-V0) 

cover

 

Material of impeller

 

Aluminium sheet 

Housing material

 Die-cast 

aluminium 

Direction of rotation

 

Clockwise, seen on rotor 

Type of protection

 IP 

20 

Insulation class

 

"B" 

Mounting position

 

Any 

Cooling bore / aperture

 Rotor-side 

Premix

 

If gas is premixed in the blower, a 
special blower must be used. 

Motor bearing

 

Ball bearing 

Technical features

 

- Control input PWM 

- Motor current limit 

- Tach output 
- Overtemperature-protected motor 

Leakage current

 

<= 3.5 mA 

Electrical leads

 

With plug 

Motor protection

 

Thermal overload protector (TOP) wired 
internally 

Approval

 

UL 507; CSA C22.2 Nr.113 

For cyclic speed loads, note that the rotating parts of the device 
are designed for maximum one million load cycles. If you have 
specific questions, contact ebm-papst for support. 

immunity

 

EMC interference

 

emission

 

 

Acc. to EN 61000-6-3 (household 
environment) 

 
 
 
 
 
 
 

Item no.: 50103-5-9970 · Revision: 70943 · Print-out: 2012-04-11 · Y. Uhlmann (VM-TDO) · Page 6 / 12 

ebm-papst Mulfingen GmbH & Co. KG · Bachm

ь

hle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · [email protected] · www.ebmpapst.com 

T

ranslation of

 the 

or

iginal oper

ating instr

uctions

Содержание G1G170-AB05-20

Страница 1: ...rdous situations and important safety regulations DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Compliance with the measures is mandato...

Страница 2: ...r open the blower WARNING Rotating device Long hair loose items of clothing and jewellery could become entangled and pulled into the device You could be injured Do not wear any loose clothing or jewel...

Страница 3: ...ith the permitted ambient temperature see chapter 3 5 Transport and storage conditions and chapter Only using the device in stationary systems Installing the device into an overall system for moving a...

Страница 4: ...ating instructions Item no 50103 5 9970 Revision 70943 Print out 2012 04 11 Y Uhlmann VM TDO Page 4 12 ebm papst Mulfingen GmbH Co KG Bachm hle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 11...

Страница 5: ...male connector No 926 884 1 L N PE 5 pole strip mating connector not included in delivery Molex No 39 01 4050 female connector Molex No 39 00 0059 Speed monitoring Not assigned PWM input Bleeder conne...

Страница 6: ...tomer specs cu customer unit Subject to alterations 3 3 Technical description Mass 4 35 kg Size 170 mm Surface of rotor Coated in black Material of protective Polyflam RPP 374 ND CS1 UL 97 V0 cover Ma...

Страница 7: ...ided Before working on the electrical connection the connections to the mains supply and PE must be shorted using an all pole disconnecting switch When working on the device you must switch off the sy...

Страница 8: ...on the device you must switch off the system machine in which the device is installed and secure it from being switched on again Check the PIN assignment of your connector Connect the panel connector...

Страница 9: ...ing output connection monitoring circuit output 3 pulses per revolution current source 1 mA Not assigned PWM 2 6 kHz control input PWM on n 100 PWM low n 0 GND Connection for control interface Item no...

Страница 10: ...to the PWM control input if you are using the PWM control input Apply the nominal voltage to the voltage supply Start the device by changing the input signal 4 7 Switching off the device Switching off...

Страница 11: ...s supply voltage for a min of 25 s and switch it on again Ambient temperature Reduce the ambient too high temperature Reset by reducing control input to 0 Unacceptable Correct the operating operating...

Страница 12: ...pection At least every 6 months Visual inspection At least every 6 months Visual inspection At least every 6 months Repair or replacement of the device Replacement of the device Fasten Fasten Replace...

Страница 13: ...Translation of the original operating instructions...

Отзывы: