5

Connection and start-up

5.1 Mechanical connection

Danger

Mechanical connection should be performed first

before electrical hookup.

Make sure that the cables are de-energized.

Secure against renewed switch-on of the operating

voltage.

Never work on live parts.

Caution

Heavy loads when removing device

Risk of physical injury, such as back injuries!

Two people are required to lift the device out of the

packaging if it weighs more than 10 kg.

Use suitable hoisting equipment if the device

weighs more than 50 kg.

You should also observe the relevant

specifications in national guidelines and

regulations.

Caution

Cutting and crushing hazard

Cutting or crushing hazard when the device is

removed from the packaging!

Lift the device carefully out of the packaging,

taking care to avoid impact.

Wear safety shoes and cut-resistant safety gloves.

Danger

Electrically charged device!

Electric shock, risk of injury!

Stand on a rubber mat when working on the

electrically charged device.

Warning

Live terminals and connections even with the device

switched off

Electric shock!

Wait five minutes after disconnecting the voltage

at all poles before opening the device or removing

the driving/steering system.

5.1.1 Requirements

Caution

Avoid electrostatic charging

Electrostatic charging could destroy the electronic

components. Ensure ESD protection during the entire

disassembly and installation process.

Check the product for transportation damage. Damaged

products must not be installed.

The impeller is only to be replaced in a dry environment

with a non-condensing atmosphere.

Ingress of moisture due to fog or precipitation may destroy

the driving/steering system.

Do not subject the cables to impermissible strain.

5.1.2 Disassembling the driving/steering system

Caution

Voltage at the product

Electric shock

De-energize the driving/steering system.

Secure it to prevent it from being switched back

on.

Ensure safely isolated from supply.

Observe the waiting time on account of capacitor

voltage. The wait time is at least 5 minutes.

Warning

Hot housing surface

Risk of injury

Ensure sufficient protection against accidental

contact.

Note

Further information can be found in the product's

operating instructions. You can find the relevant

current version of these operating instructions on our

homepage www.ebmpapst.com.

1. Unplug the cables’ plug connections.

2. Loosen the fastening screws. 

(depending on the installation position: attachment on top

driving/steering system 4 screws; attachment to side of dri-

ving/steering system 8 screws)

Содержание ArgoDrive AD-80.7

Страница 1: ...ous situation which results in slight or minor injury or damage to property if the specified actions are not taken Note A potentially harmful situation can occur and if not avoided will lead to proper...

Страница 2: ...uct This applies for the entire service life of the equipment in which this product is installed 3 1 Improper use In particular use of the product in the following ways is prohib ited and can be hazar...

Страница 3: ...peration please refer to the operating instructions of the product for which this impeller is intended 4 4 Scope of delivery 80 8217200284 Scope of delivery Num ber Note Impeller dia 80x30 1x cyl scre...

Страница 4: ...ctions even with the device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device or removing the driving steering system 5 1 1 Requireme...

Страница 5: ...otate freely by 360 2 Mark out one of the two holes on the rear of the impeller with the bearing needle 4x24 8 provided Turn the impeller with the bearing needle anti clockwise until the pin is restin...

Страница 6: ...eedle dia 24 8 9 Tighten the hexagon bolt ISO 4014 M8x40 supplied to 36 Nm 1 Nm with a WAF13 open ended wrench 10 Release wheel blockage by removing the bearing needle dia 4x24 8 11 Remove the two M2...

Страница 7: ...m www ebmpapst com 5 1 4 Changing the impeller AD 100 12 1 Open the six M6x45 screws with a WAF5 Allen key 2 Screw the two M2 5x12 screws supplied into the marked holes with an Allen wrench WAF2 until...

Страница 8: ...w ebmpapst com 8 Remove the two M2 5x12 screws with an Allen wrench WAF2 and check whether the two latches fall onto the slip hub again Danger Ensure brake function If the two M2 5x12 screws have not...

Страница 9: ...ix M6x40 screws with a WAF5 Allen key 2 Screw the two M3x12 screws supplied into the marked holes with an Allen wrench WAF2 5 until the latches can no longer come into contact with the cams in the sli...

Страница 10: ...tem Note Further information can be found in the product s operating instructions You can find the relevant current version of these operating instructions on our homepage www ebmpapst com 1 Mount the...

Страница 11: ...ns Note Further information can be found in the product s operating instructions You can find the relevant current version of these operating instructions on our homepage www ebmpapst com 6 Maintenanc...

Отзывы: