AQUMI
48
49
Dirty filter.
See the CLEAN FILTER section.
The Humidity Control may
not be set low enough.
For drier air, press the button to lower
the percent humidity desired in the room or
set the dehumidifier to
for maximum
dehumidify.
Doors and windows may
not be closed tightly.
Check that all doors, windows, and other
openings are securely closed.
Clothes dryer may be
blowing moist air into the
room.
Install the dehumidifier away from the dryer.
The dryer should be vented outside.
Room temperature is too
low.
Moisture removal is best at higher room
temperatures. Lower room temperatures
will reduce the moisture removal rate.
This model is designed to operate at
temperatures above
5°C(41°F).
Appliance runs too long.
The area is too large.
The capacity of the appliance can not meet
the area of the room.
Doors and windows are
open.
Close the door and window.
Frost appears on heat-
exchanger.
Appliance run recently or
the room temperature is
too low.
It is normal, frost usually disappear in 60
min.
Fan noise.
The air is passing through
the appliance.
This is normal
Water on the floor.
The drain connection may
be aging or loose.
Check the drain connection and the
appliance is placed level.
The drain pipe is
connected, but the water is
not drained.
If use the bucket, remove the drain pipe and
put back the drain cover; or install the drain
pipe correctly.