12
Specifications
Materials and accessories
Compare with the contents in your kit. Check the label on
the cable reel to ensure that you have received the correct
cable length.
Because the heating cable may neither be cut nor crossed,
installation must be carefully planned so that the cable is
correct for the room. Use the metre marking on the cable
after half the installation to make any adjustments to c/c
distances and to avoid surplus heating cable once the
calculated area has been covered.
Do as follows to find the exact c/c distance for cable
laying. Calculate the room's floor area. Subtract for fixed
furnishings, such as cabinets and counters, so that you
obtain the free floor area. Divide the free floor area by the
c/c distance (m) =
free floor space (m²)
cable length (m)
x 100
Plan the installation
Calculate the c/c distance
cable length to obtain the c/c distance. Depending on the
c/c distance, output varies per square metre. In the table,
Specifications
, you can see the output for various c/c
distances.
Heating cable
Tiles, linoleum
Primer
Screed/Fix
Specifications
Only on concrete
subflooring
Cable Kit
500
Cable Kit
200
Cableflex
11
Output Length
Nominal
specified
heating output
Max cont.
heat
output
AREA
75 W/m²
AREA
110 W/m²
AREA
140 W/m²
AREA
160 W/m²
Resist-
ance*
89 610 80
89 608 38
89 601 02
100 W
8.9 m
0.1 kW
0.1 kW
1.1 m²
0.8 m²
0.6 m²
0.5 m²
534
Ω
89 610 81
89 608 50
89 601 04
150 W
13.5 m
0.15 kW
0.15 kW
2.0 m²
1.35 m²
1.1 m²
0.9 m²
350
Ω
89 610 82
89 608 51
89 601 06
200 W
18.5 m
0.2 kW
0.2 kW
2.7 m²
1.85 m
1.5 m²
1.3 m²
260
Ω
89 610 83
89 608 52
89 601 08
260 W
23 m
0.26 kW
0.26 kW
3.4 m²
2.3 m²
1.8 m²
1.6 m²
207
Ω
89 610 84
89 608 53
89 601 10
330 W
31 m
0.33 kW
0.33 kW
4.4 m²
3.1 m²
2.3 m²
2.1 m²
161
Ω
89 610 85
89 608 54
89 601 12
400 W
37 m
0.4 kW
0.4 kW
5.3 m²
3.7 m²
2.8 m²
2.5 m²
133
Ω
89 610 86
89 608 55
89 601 14
470 W
43 m
0.47 kW
0.47 kW
6.3 m²
4.3 m²
3.4 m²
3.0 m²
112
Ω
89 610 87
89 608 56
89 601 16
540 W
49 m
0.49 kW
0.49 kW
7.2 m²
4.9 m²
3.9 m²
3.4 m²
98
Ω
89 610 88
89 608 57
89 601 18
650 W
58 m
0.65 kW
0.65 kW
8.7 m²
5.8 m²
4.7 m²
4.1 m²
81
Ω
89 610 89
89 608 58
89 601 20
810 W
73 m
0.81 kW
0.81 kW
10.7 m²
7.3 m²
5.8 m²
5.0 m²
66
Ω
89 610 90
89 608 59
89 601 22
960 W
86 m
0.96 kW
0.96 kW
12.8 m²
8.6 m²
6.9 m²
6.0 m²
55
Ω
89 610 91
89 608 60
89 601 24
1180 W
107 m
1.18 kW
1.18 kW
16.05 m²
10.7 m²
8.4 m²
7.4 m²
45
Ω
89 610 92
89 608 61
89 601 26
1380 W
124 m
1.38 kW
1.38 kW
18.3 m²
12.4 m²
9.8 m²
8.6 m²
38
Ω
89 610 93
89 608 62
89 601 28
1710 W
155 m
1.71 kW
1.71 kW
22.7 m²
15.5 m²
12.2 m²
10.7 m²
31
Ω
89 610 94
89 608 63
89 601 30
2080 W
187 m
2.08 kW
2.08 kW
27.7 m²
18.7 m²
14.9 m²
13.0 m²
25
Ω
Supplementary kit without thermostat for Cable Kit 500/200:
89 608 90
1180 W
107 m
1.18 kW
1.18 kW
16.05 m²
10.7 m²
8.4 m²
7.4 m²
45
Ω
*Tolerance -5 % - +10 %
Accessories
Cable Clip (89 609 58)
Cable Board (89 601 80)
Tape (89 353 49)
Sensor hose (89 605 41)
Adhesive sticks (16 939 93)
Included in package:
CK 500 CK 200 Cableflex 11
Underfloor heating cable (2.5 m connection cable) X
X
X
Thermostat with sensor cable
X
X
Spiral tube with adapter
X
X
Adhesive sticks
X
X
Reel bracket
X
X
X
Sign Heating Cable Installed
X
X
X
Existing floors (chipboard, plasterboard
or concrete) with Cable Board/Thermo
Board insulation board, if any.
On EPS concrete/cement, reinforcement
mesh is required. When laying on rein-
forcement mesh, the cable must be laid
on the top of the reinforcement mesh.