Tel 800 992 5013 / +1 508 234 6158
|
www.eaw.com
24
Line Array
Application Guide
4. Input Section:
Adjust gain, invert polarity, and set delay or delay distance.
5. Input Channels:
Signal meters and channel labels. To change a channel label, double click on
the default letter/number and type in a friendly name.
6. Output Channels:
Signal meters and channel labels. To change a channel label, double click
on the default letter/number and type in a friendly name.
7. Input/Output Color Indicators:
An easy method to distinguish which outputs are utilizing
which input source (Assigned output channels will match the color of input channels).
UXA Output Section
1. EQ/Filter Graphic Window:
Click and drag functionality to control a Low/High Pass Filters,
Low/High Shelf EQs, and (6) PEQ Filters. Clicking the right facing arrow at the top corner expands
and hides the detail pane. Once a Greybox is loaded, only the HPF may be modified.
2. EQ/Filters Section:
Manually adjust settings for all EQ/Filter bands. Use << >> buttons to
navigate from one band to the next. There is an additional pull-down menu to choose type of
filter. Once a Greybox is loaded, only the HPF may be modified.
Содержание UXA4410 series