Special Seals
(Omit if not required)
F3 - Seals for fire resistant fluids.
F6 - Seals for water glycol.
Directional Control Valve
DG5V - Subplate mounting; solenoid
controlled; pilot operated. Pressure
rating 350 bar (5000 psi) for P, A, & B
ports.
Note
Note: 210 bar (3000 psi) for pressure
centered D models.
Valve Size
10 - Valve size CETOP 10, ISO 4401-10,
NFPA D10
Pilot Valve Type
H - CETOP 3 mounting pattern, High
performance
S - CETOP 3 mounting pattern, Std.
performance
A - CETOP 5 mounting pattern, Air gap
F - CETOP 5 mounting pattern, Wet
armature
V - CETOP 5 mounting pattern, Wet
armature
W -CETOP 5 mounting pattern, Wet
armature
(See page NO TAG for descriptions)
Reducer Module
(Omit if not required)
R - A (air gap) and W (wet armature)
piloted models when pilot pressure
exceeds 210 bar (3000 psi); F and V
(wet armature) when pilot pressure
exceeds 310 bar (4500 psi).
Gauge Ports
Blank - .4375-20 UNF-2B Thread
B -
1
/
4
BSP Thread
M -ISO 6149 port
Spool Types
0 -
Open to T all ports
1 -
Open P&A to T, closed B
2 -
Closed to T all ports
Fast Response
X - (Omit for standard internal pilot
pressure models)
Note
Not available for pilot pressures above
210 bar (3000 psi), pressure centered
models must have ‘DA’ 20-70 bar
(300-1000 psi) in model code. Not
available for H or S piloted models.
Spool Control Modifications
(Omit if not required)
1 - Stroke adjustment (both ends)
(available on B, C, & N models)
2 - Pilot choke adjustment (available
on all models)
3 - Pilot choke and stroke adjustments
(both ends) (available on B, C, & N
models)
7 - Stroke adjustment on cylinder ‘A’
end only (available on A, B, C, & N
models)
8 - Stroke adjustment on cylinder ‘B’
end only (available on AL, B, C, N,
& D(*) models)
2-7 - If both are required (available on A,
B, C, & N models)
2-8 - If both are required (available on
AL, B, C, N, & D(*) models)
CAUTION
Stroke adjust pilot pressure
models are rated to a
maximum of 210 bar (3000
psi). Use reducer module if pilot
pressure exceeds 210 bar (3000 psi).
External Pilot Pressure
E -External pilot pressure. Omit for
internal pilot pressure models.
Internal Pilot Drain
T - Internal pilot drain to ‘T’ port. Omit for
external pilot drain models.
Check Valve in Pressure Port
Not available for D(*) models.
Omit if not required.
K - 0,3 bar (5 psi) check
Q - 2,5 bar (35 psi) check
R - 3,5 bar (50 psi) check
S - 5, bar (75 psi) check
1
2
3
4
5
8
7
6
3 -
Closed P&B, open A to T
4 -
Tandem P to T, closed crossover
6 -
Closed P only, open A&B to T
7 -
Open P to A&B, closed T
8 -
Tandem P to T, open crossover
9 -
Open to T all ports over tapers
11 - Open P&B to T, closed A
31 - Closed P&A, open B to T
33 - Closed P, open A&B to T over tapers
52 - Closed center, regen. by sol. ‘A’
56 - A&B to T, P blocked, regen.
by sol. ‘A’
521 - Closed center, regen. by sol. ‘B’
561 - A&B to T, P blocked, regen.
by sol. ‘B’
Spool/Spring Arrangement
A -
Spring offset
B -
Spring centered with solenoid ‘A’
removed
C -
Spring centered
D -
Pressure centered 210-350 bar
(2000-3000 psi)
DA - Pressure centered 20-70 bar
(300-1000 psi)
DB - Pressure centered 70-210 bar
(1000-2000 psi)
N -
Detented
Left Hand Build
L - Single solenoid models only, omit
if not required.
Manual Override Options
CETOP 3 piloted models only, omit if not
required.
Blank - Plain override in solenoid ends
only.
H -
Waterproof override in solenoid
ends only.
H2- Waterproof override in both ends of
single solenoid.
P2 - Plain override in both ends of single
solenoid.
Y - Lockable manual override in
solenoid ends only.
Z - No override in either end.
9
10
11
12
13
14
2
3
4
7
5
8
1
10
11
12
13
14
15
16 17
18
19
9
26
20 21 22
23
24
25
27
6
28
15
Model Code