2018.12.12
© 2017 Eaton. All rights reserved
230
TRSM0940
Service Procedures
|
Rail Position Sensor Removal and Installation
Rail Position Sensor Installation
1.
Align sensor tabs with the slot in the X-Y Shifter Rail.
Then, insert the Rail Position Sensor, with gasket, into
its mounting location.
Note:
Install the sensor, so connector opening faces
right side of the Transmission. (As viewed from the
rear of the transmission)
2.
Using a 5/32” hex key wrench, install the 2 hex key
mounting screws and tighten to 21–27 lb-in (2.3–3.0
N•m).
Caution:
Carefully hold sensor in position while install-
ing the hex key mounting screws, or sensor can snap.
3.
Reconnect the Transmission Harness to the Rail Posi-
tion Sensor.
!
Содержание UltraShift PLUS FM-14E310B-LAS
Страница 2: ...1 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Страница 4: ......
Страница 5: ...2019 07 11 2017 Eaton All rights reserved 4 TRSM0970 General Information ...
Страница 6: ...5 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Страница 7: ...2019 07 11 2017 Eaton All rights reserved 6 TRSM0970 General Information ...
Страница 8: ...7 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...
Страница 9: ...2019 07 11 2017 Eaton All rights reserved 8 TRSM0970 General Information ...
Страница 10: ...9 2017 Eaton All rights reserved 2019 07 11 General Information TRSM0970 ...