211
© 2017 Eaton. All rights reserved
2018.12.12
X-Y Shifter Removal and Installation
|
Service Procedures
TRSM0940
X-Y Shifter Installation
1.
Ensure Shift Blocks are in the Neutral position, then
move Shift Finger to the center (Neutral) location.
Note:
If the Shift Finger is not properly aligned, the X-Y
Shifter will not fit properly at its mounting location.
2.
Clean and remove old gasket material from Shift Bar
Housing. Then, install new gasket on the Shift Bar
Housing.
Note:
Apply Eaton sealant part number 71205 or equiv-
alent to the mounting cap screws before installing.
3.
The dowel pin on the X-Y Shifter must be aligned with
hole in the Shift Bar Housing.