2018.12.12
© 2017 Eaton. All rights reserved
16
TRSM0940
Service Procedures
|
LAS/VAS Auxiliary Section Removal and Disassembly
Output Yoke Removal
1.
Remove the two bolts that fasten the Output Yoke to
the Output Shaft.
2.
Remove the Output Yoke from the Output Shaft, a maul
or hammer may be required to apply force to the yoke
for removal.
LAS/VAS Auxiliary Section Removal
1.
Remove both Auxiliary Counter Shaft Bearing Covers.
Note:
Mark the covers to indicate which position they
are in as they will need to be reinstalled in the same
location.