2018.12.12
© 2017 Eaton. All rights reserved
136
TRSM0940
Service Procedures
|
Shift Bar Housing Disassembly and Assembly
9.
Move the short 1st-Reverse Gear Shift Bar to the hous-
ing rear, removing the yoke from the bar.
10.
Remove the actuating plunger from the center boss
bore.
11.
Tilt the Shift Bar Housing on its side to remove the two
3/4" interlock balls from the housing bore.