84
Line Inspection and End of Line
Grade Sensor Calibration
Process Requirements:
•
Vehicle must be on level ground before initiating the grade sensor calibration.
•
Ground surface must be /-0.5% grade (.28 degrees) level.
Failure to adhere to ground surface conditions may lead to unsatisfactory shift performance. This condition could be
misinterpreted as a product defect and could lead the operator to unnecessary repair.
•
Verify the suspension is fully aired.
•
Verify the suspension is set to proper ride height.
•
Engine shall not be running during the grade sensor calibration.
There are three options for completing the grade sensor calibration. The process for each option is listed below. Your OEM may
implement any of these processes.
Grade Sensor Calibration Tool
1.
Key On.
2.
Engine shall not be running.
3.
Plug grade sensor calibration tool into 9-pin diagnostic connector.
4.
Push the button on top of tool.
5.
Observe the pass/fail indicator on top of tool:
•
If indicator is green, the calibration was successful.
•
If indicator remains red, the calibration failed.
If the grade sensor fails to calibrate, refer to the diagnostic procedure in this publication.
WARNING
WARNING