SVPD Programming Guide

This document is intended for Lighting Control Systems professionals

Table of contents

Quick Reference Guide  ..................................................................................................................................................................... 2
Integrated sensor and remote overview  ..........................................................................................................................................

2

Features and Default Settings  ..........................................................................................................................................................

3

Making Adjustments to Default Scene Levels  .................................................................................................................................. 4
Step 1: Disable daylighting dimming (optional)  ................................................................................................................................. 4
Step 2: Set scene levels  ................................................................................................................................................................... 4
Making Adjustments to Other Settings  ............................................................................................................................................ 5
Set sensor time-out value  ................................................................................................................................................................. 5
Set sensitivity level  ........................................................................................................................................................................... 5
Enable/disable daylight switching  ..................................................................................................................................................... 5
Issuing manual commands  ............................................................................................................................................................... 5
Troubleshooting guide  ....................................................................................................................................................................... 5-7

This document applies to fixture with factory installed SVPD1, SVPD2,  

SVPD3 integrated sensors.

Содержание SVPD Series

Страница 1: ...ettings 3 Making Adjustments to Default Scene Levels 4 Step 1 Disable daylighting dimming optional 4 Step 2 Set scene levels 4 Making Adjustments to Other Settings 5 Set sensor time out value 5 Set sensitivity level 5 Enable disable daylight switching 5 Issuing manual commands 5 Troubleshooting guide 5 7 This document applies to fixture with factory installed SVPD1 SVPD2 SVPD3 integrated sensors ...

Страница 2: ...ene level 4 individual fixture Set all fixtures in the space to the desired ON OFF configuration and desired light level then save at each fixture 1 39 2 12 set occupancy time out any time individual fixture 3 50 set occupancy sensitivity any time individual fixture enable disable daylight switching any time individual fixture Sensor Video Integrated sensor and remote overview The SVPD integrated ...

Страница 3: ...on Scene Yes Adjust to any desired light level Unoccupied scene level The light level that the fixture will go to when the space remains unoccupied for the full amount of the programmed occupancy time out period OFF Yes Adjust to any desired light level Occupancy time out The period of time that the lighting will remain at the current level after the space becomes unoccupied 20 min Yes Adjust to 5...

Страница 4: ...l c Set the energy saver scene level optional The occupancy detection scene levels unoccupied scene level and energy saver scene levels are all set using the same procedure with the exception of the button being pressed to save the scene Before you begin Make scene level adjustments at night or use shading with only electric light present in the space This is critical to operation of daylight dimm...

Страница 5: ...nual commands The ISHH 01 programming remote and the ISHH 02 personal remote can issue temporary scene and raise and lower commands Manual commands will remain in effect until the occupancy time out period expires 1 Stand directly below the fixture and point the remote at the integrated sensor 2 Press the scene button ES MIN 50 Occ 75 MAX UnOcc or use the raise and lower control to adjust lighting...

Страница 6: ...C is present between the purple and gray disconnected driver leads If the lighting does go full bright when disconnected from the control module check for polarity reversal on the 0 10V leads daylight dimming is enabled where not appropriate AND OR occupancy detection scene level set too low Using the programming remote ISHH 01 ensure the relay can be turned ON OFF and the light level can be raise...

Страница 7: ...eas determine which fixtures should dim with daylighting If there are fixtures that should not daylight dim follow the steps in this document to disable daylight dimming and set the occupancy detection scene level If the fixtures should dim with daylighting they may need recalibration Follow the steps in this document to set the occupancy detection scene level If the response still does not seem a...