SONIX VW2 TECHNICAL MANUAL  

TM368 / A  May 2022  www.eaton.com

1  Introduction

These instructions are intended for all users who will 

have to install, commission, configure and setup the 

Sonix Vw2 Termination Unit.
For this, the manual is action-oriented and explains how 

to achieve a certain objective on a step-by-step basis. 

It is assumed that you have the necessary electrical, 

electronic and telecommunications experience to 

undertake the work. If in doubt, please consult Eaton.

1.1  Eaton quality assurance

Eaton design, manufacture, install and commission all 

our products to the highest standards of quality. This 

quality process is embraced and adopted throughout the 

group in all areas of our operations. 
This is demonstrated by our compliance and strict 

adherence to ISO 9001, 14001, ATEX, IECEX policies. 
On receipt of the product, ensure that the cartons are 

undamaged and that the contents are all correct and 

complete. 
Should this product reach you in an unsatisfactory 

condition please report this to Eaton to enable us to 

rectify and investigate the fault in a speedy manner.

1.2  About Sonix

The Sonix PA/GA system is designed around a highly 

secure & flexible architecture, that removes the need 

for lengthy engineering cycles, bespoke and costly 

software, custom field engineering or expensive onsite 

support. 
This results in a highly effective and flexible 

communications solution for the next generation.
The Sonix system is rigorously designed for installation 

in both safe area or potentially explosive environments, 

using latest protection philosophies including EEx-e, -d, 

-i, -m and -p to ensure the highest levels of safety whilst 

increasing operational features.
The Sonix PA/GA System is designed to meet and 

surpass the requirements of ATEX, IECEx, DNV, BV, 

ABS, IMO and PFEER, with other regional certifications 

pending.
Please refer to Sonix system technical manual for any 

further information.

1.3  About the product

Sonix Vw2 unit is a compact, high capacity beacon loop 

control and monitoring device. It autonomously monitors 

and supervises beacon cable installation and loop 

integrity with a discrete, non-visual signal, and at the 

same time operates as client to the 2Mx (PAGA Central 

Matrix controller), i.e. it receives data packets, acts on 

that data and sends a response back to the 2Mx.
The robust and industrial design of the module ensures 

its protection against open and short circuit associated 

with field loop faults. In the event of such common 

field loop faults, the Vw2 rapidly detects, reports and 

diagnoses the fault, reporting this information back to 

the 2Mx controller and the SAS (Sonix Administration 

Software – available separately from Eaton) application, 

with the latter also serving as the configuration and 

monitoring tool.
The unit – in the form of a PCB held by a din rail carrier 

– is provided with industrial beacon loop terminals to 

securely and safely isolate the field cables for testing 

and fault rectification. The Vw2 always ensures that field 

beacons are driven with power signals in both directions. 

This self-healing ring design guarantees that, in the event 

of an open circuit condition, critical visual communication 

is not lost. Additionally, the PCB form of the unit allows 

for quick and easy installation and replacement of any 

units, while keeping low rack footprint.
The Vw2 provides dual channel control and monitoring of 

beacon loops, and up to six Vw2 units can be connected, 

providing 12 channels of independent control (if more 

than 12 channels are required, please talk to the Eaton 

representative). 
Connection to the 2Mx module is maintained via a fully 

redundant, self-healing data loop consisting of two 

RJ45/Cat 6A cables – this type of connection is central 

to the architecture of the Sonix PA/GA system. This 

ensures that connectivity of the Vw2 is vastly simplified, 

plug and play, quick to install and reliable. If extra 

equipment is needed within the system, it can simply 

be added to the loop without extensive re-wiring of the 

system.
All inputs and outputs are always designed to be fail safe 

and reliable to ensure consistent, unfailing operation.

1.4  Key features

Sonix Vw2 is designed to provide the following features:

• 

 Compact and efficient DIN rail mount fixing.

• 

 Fully configurable via SAS Software.

• 

 Low rack footprint.

• 

 Monitors and reports on 2 loops of beacons.

• 

 Individual control of up to 2 loops of beacons.

• 

 High integrity field cable monitoring.

• 

 Rapid reporting of line fault conditions.

• 

 Design focused MTBF/MTTR.

• 

 Low thermal emissions.

• 

 Operating on self-healing ring.

• 

 Dual RJ45 connectivity for easy maintenance.

• 

 Dual 10A switching channels.

• 

 Field cable lightning suppression.

Содержание SONIX Vw2

Страница 1: ...SONIXTM Vw2 Termination Unit SonixTM Vw2 Technical Manual...

Страница 2: ...for a particular purpose or merchantability other than those Specifically set out in any existing contract between the parties Any such contract states the entire obligation of eaton The contents of t...

Страница 3: ...feedback 2Mx Sonix 2Mx Central controller Amp 350 d Sonix 350 W Power Amplifier with 100 V line output Eol1 Sonix Remote End of Line unit Eol8 Sonix Amplifier to 100 V line interface unit 8 channel SP...

Страница 4: ...9 4 5 1 Connecting Vw2 within standalone or A B systems 9 4 5 2 Connecting Vw2 within N 1 systems 9 4 6 Beacon power input connection 9 4 6 1 Automatic redundant power switchover 9 4 7 Beacon output...

Страница 5: ...L SIMPLIFIED VIEW OF VW2 UNIT 7 FIGURE 2 DC POWER CONNECTIONS 8 FIGURE 3 SINGLE VW2 BUS CONNECTIONS 9 FIGURE 4 MULTIPLE VW2 CONNECTIONS 9 FIGURE 5 VW2 BEACON POWER INPUT 9 FIGURE 6 REDUNDANT POWER SWI...

Страница 6: ...controller i e it receives data packets acts on that data and sends a response back to the 2Mx The robust and industrial design of the module ensures its protection against open and short circuit ass...

Страница 7: ...u remain safe throughout During this work you may be exposed to potentially hazardous voltages currents confined spaces and potentially hazardous industrial environments Prior to undertaking any work...

Страница 8: ...with signal or audio cables and reduce the possibility of interfer ence Warning Observe the polarity of incoming power supply cables Maximum cable section supported by the unit are Solid 4 0 mm2 Stra...

Страница 9: ...Vw2 Beacon power input Accepted beacon voltages are as follows if other voltages are required please contact your local Eaton representative 48 V dc 110 V ac 240 V ac Maximum cable section supported...

Страница 10: ...maximum allowable peak surge current is limited to 100 A by the on board relays The unit is fitted with a pair of 10 A 10 x 38 mm Mersen fuses part number S218194 Warning Only replace fuses with origi...

Страница 11: ...and contains system activity information from the 2Mx central controller and Vw2 status and activity going to the 2Mx 5 2 Basic operation Each output port can be configured to activate on any active...

Страница 12: ...nfigurable via SAS application A detailed description of all the configuration options is included in SAS Product Manual but some of the options are worth mentioning here for clarity and completion 6...

Страница 13: ...roved firmware The Sonix Vw2 units are controlled by a Microsemi ProASIC3 FPGA with instant on technology for fast and reliable operation To ensure correct operation of the unit it is supplied fully t...

Страница 14: ...ton and SONIX are registered trademarks All other trademarks are property of their respective owners Changes to the products to the information contained in this document and to prices are reserved so...

Отзывы: