2
Xenon beacon - SM87HXB & SM87XBT
English
4.0 Maintenance
During the working life of the unit, it should require little
or no maintenance. However, if abnormal or unusual
environmental conditions occur due to plant damage or
accident etc., then visual inspection is recommended.
If the unit requires cleaning, then only clean exterior with
a damp cloth to avoid electro-static charge build up.
If a unit fault should occur, then the unit can be repaired
by Eaton. All parts of the unit are replaceable.
If you acquired a significant quantity of units, then it is
recommended that spares are also made available.
Please discuss your requirements with the Technical Sales
Engineers at Eaton.
description
Part number
Cover assembly (Without lens guard fitted)
Contact Eaton
Cover assembly (With lens guard fitted)
Contact Eaton
O-ring (Alloy units)
PX99900312
O-ring (Stainless Steel units)
PX99900233
Electronics assembly (110Vac / 60fpm)
PX99900094
Electronics assembly (240Vac / 60fpm)
PX99900121
Electronics assembly (24Vdc / 60fpm)
PX99900099
Spare xenon tube
PX99900122
Cover screw for st. steel unit (4 off required)
PX99900584
Cover screw for alloy unit (4 off required)
PX99900818
5.0 Certification/approvals
IECEx units
Certified to IEC 60079-0, IEC 60079-1 and IEC 60079-31
Ex d unit (IEC certification No. IECEx BAS 09.0059)
Ex d IIC Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Unit type
T-rating (Tx)
ambient temp
range (Tamb.)
SM87HXB
T95°C
(-55°C to +70°C)
T80°C
(-55°C to +55°C)
T65°C
(-55°C to +40°C)
SM87XBT/A (Electronics)
T70°C
(-55°C to +55°C)
T55°C
(-55°C to +40°C)
SM87XBT/B (Xenon tube)
T110°C
(-55°C to +85°C)
T95°C
(-55°C to +70°C)
T80°C
(-55°C to +55°C)
T65°C
(-55°C to +40°C)
The IECEx certificate and product label carry the IECEx
equipment protection level marking
Gb
Db
Where Gb signifies suitability for use in a Zone 1 surface
industries area in the presence of gas.
Where Db signifies suitability for use in a Zone 21 surface
industries area in the presence of dust.
ATEX units
Certified to EN60079-0, EN60079-1 and EN60079-31
Ex d unit (ATEX certification No. Baseefa03ATEX0222)
Ex d IIC Tx (Tamb.) Gb
Ex tb IIIC Tx (Tamb.) Db IP66/IP67
Unit type
T-rating (Tx)
ambient temp
range (Tamb.)
SM87HXB
T95°C
(-55°C to +70°C)
T80°C
(-55°C to +55°C)
T65°C
(-55°C to +40°C)
SM87XBT/A (Electronics)
T70°C
(-55°C to +55°C)
T55°C
(-55°C to +40°C)
SM87XBT/B (Xenon tube)
T110°C
(-55°C to +85°C)
T95°C
(-55°C to +70°C)
T80°C
(-55°C to +55°C)
T65°C
(-55°C to +40°C)
The ATEX certificate and product label carry the ATEX
group and category marking:
II 2 GD
Where:
Signifies compliance with ATEX
II
Signifies suitability for use in surface industries
2
Signifies suitability for use in a zone 1 area
G
Signifies suitability for use in the presence of gases
D
Signifies suitability for use in the presence of dust
The ATEX certificate and product label also carry the
following mark:
1180
This signifies unit compliance to the relevant European
directives, in this case 94/9/EC, along with the number
of the notified body issuing the EC type examination
certificate.
6.0 Functional safety
Introduction
The SM87HXB Beacon has been designed for use
in potentially explosive atmospheres and harsh
environmental conditions. The marine grade alloy or
stainless steel enclosures are suitable for use offshore
or onshore, where light weight combined with corrosion
resistance and strength is required.
Xenon beacon - SM87HXb & SM87XbT- drafT 1
TM001 Issue J February 2023 www.eaton.com