background image

61

  Appendix B—Installation guidelines

POWERXL SERIES VFDS

   MN040060EN—September 2020   www.eaton.com

Table 33.  Dynamic brake resistors (continued).

Output rating

Resistor specifications

Input 

voltage

Frame  

size

Drive 

catalog 

number

CT/I

H

 

current 

amps

VT/I

L

 

current 

amps

Minimum 

resitance  

ohms

Suggested 

resistance 

ohms

10% 

duty 

cycle  

100% 

torque 

watts

20% 

duty 

cycle  

100% 

torque 

watts

40% 

duty 

cycle  

100% 

torque 

watts

50% 

duty 

cycle 

150% 

torque  

watts

20% 

duty 

cycle  

100% 

torque 

catalog 

number

50% duty 

cycle 

150% 

torque 

catalog 

number

380 Vac to 

480 Vac 

50/60 Hz 

3-phase

FR1

DM1-

341D5…

1.5

2.2

105

400

80

160

320

400

DBR- 

R100- 

W0400

DM1-

342D2…

2.2

4.3

105

400

80

160

320

400

DBR- 

R100- 

W0400

DM1-

344D3…

4.3

5.6

105

400

80

160

320

400

DBR- 

R100- 

W0400

DM1-

345D6…

5.6

7.6

105

128

250

500

1000

1250

DBR- 

R100- 

W0800

DBR- 

R100- 

W1200

FR2

DM1-

347D6…

7.6

12

35

128

250

500

1000

1250

DBR- 

R100- 

W0800

DBR- 

R063- 

W1600

DM1-

34012…

12

16

35

128

250

500

1000

1250

DBR- 

R100- 

W0800

DBR- 

R063- 

W1600

DM1-

34016…

16

23

35

80

400

800

1600

2000

DBR- 

R100- 

W0800

DBR- 

R100- 

W2000

FR3

DM1-

34023..

23

31

26

80

400

800

1600

2000

DBR- 

R100- 

W0800

DBR- 

R100- 

W2000

FR4

DM1-

34031…

31

38

17

40

800

1600

3200

4000

DBR- 

R063- 

W1600

DBR- 

R030- 

W4000

DM1-

34038…

38

46

17

40

800

1600

3200

4000

DBR- 

R063- 

W1600

DBR- 

R030- 

W4000

525 Vac to 

600 Vac 

50/60 Hz 

3-phase

FR2

DM1-

354D5…

4.5

7.5

DM1-

357D5…

7.5

10

DM1-

35010…

10

13.5

FR3

DM1-

35013…

13.5

18

FR4

DM1-

35018…

18

22

DM1-

35022…

22

27

Содержание PowerXL DM1 Series

Страница 1: ...Effective September 2020 Installation manual PowerXL DM1 and DM1 PRO Series VFDs...

Страница 2: ...ITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF THE MANUFACTURER THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME...

Страница 3: ...to find product information You can also find information on local distributors or Eaton s sales offices Website address www eaton com drives EatonCare Customer Support Center Call the EatonCare Suppo...

Страница 4: ...n warnings and cautions 11 Standard mounting instructions 11 FR1 mounting instructions 17 FR2 mounting instructions 18 FR3 mounting instructions 19 FR4 mounting instructions 20 Mounting instruction fo...

Страница 5: ...data 46 APPENDIX B INSTALLATION GUIDELINES 49 Cable and fuse sizing 49 Temperature deratings 54 Heat loss data 59 Brake resistor sizing 60 APPENDIX C DIMENSION DRAWINGS 63 APPENDIX D SAFETY INSTRUCTIO...

Страница 6: ...2 without NEMA 1 kit dimension drawing 68 Figure 16 DM1 Pro FR3 without NEMA 1 kit dimension drawing 69 Figure 17 DM1 FR3 without NEMA 1 kit dimension drawing 70 Figure 18 DM1 Pro FR4 without NEMA 1 k...

Страница 7: ...software 5 Table 14 Maintenance measures and intervals 8 Table 15 Approximate mounting dimensions in inches mm 13 Table 16 Approximate space requirements in inches mm 15 Table 17 Screw quantities 23...

Страница 8: ...one hand when checking components Always work with another person in case an emergency occurs Disconnect power before checking controllers or performing maintenance Be sure equipment is properly eart...

Страница 9: ...ditions Failure to observe this precaution could result in death or severe injury WARNING An upstream disconnect protective device must be provided as required by the National Electric Code NEC Failur...

Страница 10: ...e to follow these instructions will result in death or serious injury WARNING The drive outputs U V W must not be connected to the input voltage or the utility line power as severe damage to the devic...

Страница 11: ...iving inspection recommendations and the PowerXL DM1 Series open drive catalog numbering system and accessories available for the PowerXL DM1 Series Figure 1 Rating label Table 1 Common abbreviations...

Страница 12: ...00 hp 010 10 0 A 5 50 kW 7 50 hp 6D9 6 9 A 1 10 kW 1 50 hp 7D8 7 8 A 1 50 kW 2 00 hp 7D8 7 8 A 1 50 kW 2 00 hp 5D6 5 6 A 2 20 kW 3 00 hp 013 13 5 A 7 50 kW 10 00 hp 011 11 0 A 2 20 kW 3 00 hp 011 11...

Страница 13: ...w overload IL Frame size 480 V 50 Hz kW rating 480 V 60 Hz hp Current A 480 V 50 Hz kW rating 480 V 60 Hz hp Current A No EMC Catalog number With EMC Catalog number FR1 0 37 0 5 1 5 0 75 1 2 2 DM1 341...

Страница 14: ...3 0 75 1 4 8 DM1 323D0NB S20S DM1 323D0EB S20S 0 75 1 4 8 1 5 2 7 8 DM1 324D8NB S20S DM1 324D8EB S20S 1 5 2 7 8 2 2 3 11 DM1 327D8NB S20S DM1 327D8EB S20S FR2 2 2 3 11 4 5 17 5 DM1 32011NB S20S DM1 3...

Страница 15: ...CC FR4N1KIT DXM ACC FR1N1KIT PLENUM DM1 FR1 Plenum Rated NEMA 1 Kit DXM ACC FR2N1KIT PLENUM DM1 FR2 Plenum Rated NEMA 1 Kit DXM ACC FR3N1KIT PLENUM DM1 FR3 Plenum Rated NEMA 1 Kit DXM ACC FR4N1KIT PLE...

Страница 16: ...nd on the cover of the control terminals Information concerning the guarantee can be found in the General Terms and Conditions of Sale Chapter 2 Receiving and inspection The PowerXL DM1 VFD has met a...

Страница 17: ...Receiving and inspection POWERXL SERIES VFDS MN040060EN September 2020 www eaton com Unpacking Lift the drive out from the carton and remove the packaging Figure 3 Unpacking FR1 FR2 FR3 and FR4 FR1 F...

Страница 18: ...ass Observe the technical data and connection requirements For additional information refer to the equipment nameplate or label at the frequency inverter and the documentation Any other usage constitu...

Страница 19: ...ounding measures further steps are superfluous Input voltage and frequency The standardized input voltages IEC 60038 VDE017 1 for energy suppliers EVU guarantee the following conditions at the transit...

Страница 20: ...n devices Special compensation measures on the power supply side is not required for PowerXL Series drives which take on very little reactive power of the fundamental harmonics from the AC power suppl...

Страница 21: ...arthing conductor must be connected or the cross section of the equipment grounding conductor must be at least 10 mm2 Cu WARNING The components in the drive s power section remain energized after the...

Страница 22: ...ERIES VFDS MN040060EN September 2020 www eaton com Figure 7 Mounting orientation 90 90 90 Vertical mounting surface Inclined mounting surface Horizontal mounting surface Inclined mounting Vertical mou...

Страница 23: ...140 2 83 72 2 26 57 5 2 26 57 5 0 20 5 2 2 6 1 2 FR2 DM1 127D8 7 8 11 7 09 180 8 66 220 8 15 207 4 29 109 3 56 90 5 3 56 90 5 0 22 5 5 5 7 2 6 DM1 12011 11 17 5 7 09 180 8 66 220 8 15 207 4 29 109 3 5...

Страница 24: ...012 12 16 7 09 180 8 66 220 8 15 207 4 29 109 3 56 90 5 3 56 90 5 0 22 5 5 5 7 2 6 DM1 34016 16 23 7 09 180 8 66 220 8 15 207 4 29 109 3 56 90 5 3 56 90 5 0 22 5 5 5 7 2 6 FR3 DM1 34023 23 31 7 09 180...

Страница 25: ...DM1 121D6 1 6 2 5 0 0 1 97 50 1 97 50 14 83 25 2 DM1 123D0 3 4 8 0 0 1 97 50 1 97 50 14 83 25 2 DM1 124D8 4 8 7 8 0 0 1 97 50 1 97 50 14 83 25 2 FR2 DM1 127D8 7 8 11 0 0 1 97 50 1 97 50 24 72 42 DM1...

Страница 26: ...1 97 50 14 83 25 2 FR2 DM1 347D6 7 6 12 0 0 1 97 50 1 97 50 37 43 63 6 DM1 34012 12 16 0 0 1 97 50 1 97 50 37 43 63 6 DM1 34016 16 23 0 0 1 97 50 1 97 50 37 43 63 6 FR3 DM1 34023 23 31 0 0 1 97 50 1 9...

Страница 27: ...I version only The input wires including 3 line wires and 1 input grounding wire should run through the input magnetic core before connecting to input terminal block and grounding hole Use a cable tie...

Страница 28: ...e wires and one input grounding wire should run through the input magnetic core before connecting to input terminal block and grounding hole Use a cable tie to secure the input magnetic cores to the i...

Страница 29: ...magnetic core before connecting to the input terminal block and grounding hole Use a cable tie to secure the input magnetic cores to the input wires For 3 phase FR3 EMI version the output wires only...

Страница 30: ...t magnetic core before connecting to input terminal block and grounding hole Use a cable tie to tie the input magnetic cores to the input wires The output wires only 3 motor wires should run through t...

Страница 31: ...p 1 For enclosed type Remove the front cover 1 from NEMA 1 kit then remove the terminal cover 2 from drive For open type Only remove the terminal cover Step 2 Remove the option card port label and fou...

Страница 32: ...le with the optional card port Mount the option card to the drive by inserting the four snaps into the slots on drive Step 5 For enclosed type Install the terminal cover 1 to the drive then install th...

Страница 33: ...rail mounting 2 The NEMA 1 kits are only applicable for vertical mounting but not for horizontal mounting or inclined mounting Component list for DM1 NEMA 1 kit Table 17 Screw quantities M3 x 8 M3 x 1...

Страница 34: ...hen push the two hooks on thicker end of fan cover into the two slots on top surface of drive The thicker end of the fan cover should face the front surface of drive Step 2 Remove the two screws NEMA...

Страница 35: ...without the output grounding wire through the output magnetic core Connect the motor wires to U V W terminals Leave the output grounding wire unconnected Tie output magnetic core to the output wires w...

Страница 36: ...to the drive Mount NEMA 1 kit front cover back to the conduit box with screws See B Installation steps for DM1 FR2 FR4 NEMA 1 kits Step 1 Align the four hooks on fan cover with the four slots around...

Страница 37: ...ding rectangular openings on drive bottom surface then use two screws to fix the conduit box to the metal grounding plate of drive See B Step 3 Remove the two screws and NEMA 1 kit bottom plate See A...

Страница 38: ...to the output wires with a cable tie Use the EMC grounding clamp and two screws to fix output cable shielding layer See B Power wiring for non EMI version drive 1 Run input cable including three line...

Страница 39: ...over back to the NEMA 1 kit main frame with two screws Keypad remote mounting kit Remote keypad kit component list 1 Keypad mounting bezel with adapter board and seal strip pre installed 2 Male to mal...

Страница 40: ...cable to the female connector of the adapter board and the other end connect to the drive inside the cabinet Step 3 Push the keypad into the mounting bezel and connect it to the drive inside the cabi...

Страница 41: ...SERIES VFDS MN040060EN September 2020 www eaton com 2 Connect the female RJ45 port of remote keypad kit and computer with a RJ45 cable Keypad mounting template Computer Female RJ45 port 95 3 74 110 4...

Страница 42: ...same cross sectional area as the original protective earthing conductor must be connected or the cross section of the equipment grounding conductor must be at least 10 mm2 Cu WARNING The components in...

Страница 43: ...2 Control wire torque in lb N m AI DI RO 100 Vac to 120 Vac 50 60 Hz 1 phase FR1 DM1 111D6 1 6 2 5 14 2 5 4 4 0 5 10 2 5 7 1 0 8 28 16 0 5 1 5 AI DI 1 73 0 2 RO 4 5 0 5 4 5 0 5 DM1 113D0 3 4 8 10 6 4...

Страница 44: ...4 3 14 2 5 4 4 0 5 14 2 5 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 DM1 344D3 4 3 5 6 14 2 5 4 4 0 5 14 2 5 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 DM1 345D6 5 6 7 6 14 2 5 4 4 0 5 10 2 5 7 1 0 8 28 16 0...

Страница 45: ...20 6 12 6 200 Vac to 240 Vac 50 60 Hz 1 phase FR1 DM1 121D6 1 6 2 5 4 6 5 15 15 15 14 14 18 8 16 8 DM1 123D0 3 4 8 8 11 30 30 30 14 10 18 8 16 8 DM1 124D8 4 8 7 8 11 17 60 63 60 10 8 18 8 16 8 FR2 DM...

Страница 46: ...1 14 4 30 20 XTPR016DC1 XTPAXLSAD or PKZM4 16 BK50 3 PKZ4 E 20 12 10 20 6 12 8 DM1 34012 12 16 14 4 19 2 40 25 XTPR025DC1 XTPAXLSAD or PKZM4 25 BK50 3 PKZ4 E 30 10 10 20 6 12 8 DM1 34016 16 23 19 2 2...

Страница 47: ...4 4 0 2 6 1 5 6 FR2 DM1 32011 11 17 5 12 7 20 1 40 30 25 30 6 6 0 5 16 4 10 DM1 32017 17 5 25 3 20 1 29 1 60 40 32 45 10 10 0 5 16 4 10 FR3 DM1 32025 25 3 32 2 29 1 37 70 50 40 50 10 10 0 5 16 6 10 F...

Страница 48: ...38 Chapter 5 Electrical installation POWERXL SERIES VFDS MN040060EN September 2020 www eaton com Installation overview for DM1 2 DM1...

Страница 49: ...RY1NO 19 RY1CM 20 RY1NC 21 RY2NO 22 RY2CM 8 AI1 9 AI1 10 GND 11 AO1 12 GND 13 10 V 14 24 V 1 DIN1 2 DIN2 3 DIN3 4 DIN4 5 CMA 6 A 7 B Relay terminals I O terminals 18 RY1NO 19 RY1CM 20 RY1NC 1 DIN1 2...

Страница 50: ...signal ground I O ground for reference and control 11 AO1 Analog output 1 Output frequency Shows output frequency to motor 0 60 Hz 4 mA to 20 mA 12 GND I O signal ground I O ground for reference and c...

Страница 51: ...en drive and motor DO NOT USE conduit as ground CAUTION Improper grounding could result in damage to the motor and or drive and could void warranty Checking the cable and motor insulation 1 Check the...

Страница 52: ...oors should make good contact and be connected with short HF braided cables It is recommended to avoid using painted surfaces anodized chromized An overview of all EMC measures is provided in Figure 8...

Страница 53: ...Control and signal lines 1 to 24 fieldbus connection large area connection of all metallic control panel components Mounting surfaces of frequency inverter and cable shielding must be free from paint...

Страница 54: ...lded connection cables should not be any longer than about 200 mm Table 24 Environment EMC levels Cable Type Category C2 Category C3 Category C4b Line voltage mains 1 1 1 Motor cable 3c 3 3 Control ca...

Страница 55: ...t wiring work only if the unit is de energized After disconnecting the supply wait at least five minutes before removing the cover to allow the intermediate circuit capacitors to discharge WARNING Fai...

Страница 56: ...bient temperature maximum 40 C up to 60 C with derating overload 1 1 x IL 1 min 10 min IH ambient temperature maximum 50 C up to 60 C with derating overload 1 5 x IH 1 min 10 min Overload current 150...

Страница 57: ...ference voltage 10 3 Vdc max 10mA Digital Inputs Quantity 4 programmable Type Positive or negative logic 18 to 30 Vdc Maximum switching speed 1 kHz Relay output Quantity 2 programmable 1 Form C relay...

Страница 58: ...ation 15 g Duration 11 ms Transportation ISTA 1 A Transported as a single device in a separate package Vibartion test and drop test per ISTA 1A Overvoltage Overvoltage Category III Pollution degree Po...

Страница 59: ...30 30 14 10 18 8 16 8 DM1 113D0 3 4 8 13 5 20 70 63 70 10 8 18 8 16 8 FR2 DM1 114D8 4 8 6 9 20 26 4 90 63 90 8 8 20 6 12 6 DM1 116D9 6 9 7 8 26 4 30 125 63 125 8 6 20 6 12 6 200 Vac to 240 Vac 50 60...

Страница 60: ...D or PKZM4 40 BK50 3 PKZ4 E EGC3050FFG 8 8 20 6 10 8 FR4 DM1 32032 32 2 48 3 35 4 53 1 100 EGC3080FFG 4 8 20 2 8 6 DM1 32048 48 3 62 1 53 1 68 3 125 EGC3100FFG 3 6 20 2 8 6 380 Vac to 480 Vac 50 60 Hz...

Страница 61: ...65 kAIC Recom mended inverse time molded case circuit breaker max rating 100 kAIC open type only for 3 phase NEC wire size line and motor AWG NEC wire size ground AWG Term inal size line and motor AWG...

Страница 62: ...20 26 4 90 63 90 10 10 0 5 16 1 10 DM1 116D9 6 9 7 8 26 4 30 125 63 125 10 10 0 5 16 1 10 200 Vac to 240 Vac 50 60 Hz 1 phase FR1 DM1 121D6 1 6 2 5 4 6 5 15 15 15 2 5 2 5 0 2 6 1 6 DM1 123D0 3 4 8 8...

Страница 63: ...ne and motor mm2 Term inal size ground mm2 380 Vac to 480 Vac 50 60 Hz 3 Phase FR1 DM1 341D5 1 5 2 2 1 8 2 6 6 4 6 3 15 2 5 2 5 0 2 6 1 5 6 DM1 342D2 2 2 4 3 2 6 5 2 10 8 6 3 15 2 5 2 5 0 2 6 1 5 6 DM...

Страница 64: ...r constant operating temperature enclosure rating switching frequency required amperage Follow the below steps to correctly de rate the PowerXL drives 1 Find the derating table Table 30 Table 31 for t...

Страница 65: ...3A 63 57 10 75 A 61 43 10 38 A 59 29 10 A 57 14 9 63 A 55 9 25 A 52 86 8 88 A 50 71 8 5 A 48 57 FR3 40 C 25 3 A 100 25 3 A 100 25 3 A 100 25 3 A 100 25 3 A 100 25 3 A 100 25 3 A 100 25 3 A 100 24 8 A...

Страница 66: ...8 46 7 9 9 42 9 9 0 39 1 8 1 35 3 7 3 31 5 6 4 27 7 5 5 23 9 60 C 14 0 60 9 14 0 60 9 14 0 60 9 14 0 60 9 13 1 57 1 12 3 53 3 11 4 49 5 10 5 45 7 9 6 41 8 8 8 38 0 7 9 34 2 7 0 30 4 6 1 26 6 5 3 22 8...

Страница 67: ...100 17 5 A 100 17 5 A 100 17 5 A 100 17 5 A 100 17 5 A 100 17 5 A 100 17 5 A 100 17 38 A 99 29 17 25 A 98 57 17 13 A 97 86 17 A 97 14 16 88 A 96 43 16 75 A 95 71 16 63 A 95 16 5 A 94 29 50 C 17 5 A 10...

Страница 68: ...0 8 67 2 9 9 61 7 9 0 56 3 8 1 50 8 7 3 45 3 6 4 39 8 5 5 34 4 60 C 14 0 87 5 14 0 87 5 14 0 87 5 14 0 87 5 13 1 82 0 12 3 76 6 11 4 71 1 10 5 65 6 9 6 60 2 8 8 54 7 7 9 49 2 7 0 43 8 6 1 38 3 5 3 32...

Страница 69: ...FR1 DM1 321D6 1 6 2 5 12 8 22 33 14 83 25 2 56 9 DM1 323D0 3 4 8 12 8 37 6 46 4 14 83 25 2 56 9 DM1 324D8 4 8 7 8 12 8 42 85 14 83 25 2 56 9 DM1 327D8 7 8 11 12 8 75 99 14 83 25 2 56 9 FR2 DM1 32011...

Страница 70: ...60 Hz 1 phase FR1 DM1 121D6 1 6 2 5 36 100 80 160 320 400 DBR R100 W0400 DM1 123D0 3 4 8 36 100 80 160 320 400 DBR R100 W0400 DM1 124D8 4 8 7 8 36 100 80 160 320 400 DBR R100 W0400 FR2 DM1 127D8 7 8...

Страница 71: ...400 DBR R100 W0400 DM1 342D2 2 2 4 3 105 400 80 160 320 400 DBR R100 W0400 DM1 344D3 4 3 5 6 105 400 80 160 320 400 DBR R100 W0400 DM1 345D6 5 6 7 6 105 128 250 500 1000 1250 DBR R100 W0800 DBR R100 W...

Страница 72: ...DM1 113D0 3 4 8 1 6 2 5 1 3 1 6 1 1 3 FR2 DM1 114D8 4 8 6 9 3 4 8 1 6 2 5 1 3 1 6 DM1 116D9 6 9 7 8 4 8 6 9 3 4 8 1 6 2 5 200 Vac to 240 Vac 50 60 Hz 1 phase FR1 DM1 121D6 1 6 2 5 1 3 1 6 1 1 3 0 8 1...

Страница 73: ...2 1 1 1 5 0 9 1 1 2 6 5 2 1 8 2 6 1 5 1 8 1 2 1 5 DM1 344D3 4 3 5 6 2 2 4 3 1 5 2 2 1 1 1 5 5 2 6 7 2 6 5 2 1 8 2 6 1 5 1 8 DM1 345D6 5 6 7 6 4 3 5 6 2 2 4 3 1 5 2 2 6 7 9 1 5 2 6 7 2 6 5 2 1 8 2 6 FR...

Страница 74: ...91 0 71 98 93 95 75 0 87 50 50 50 0 91 37 39 37 0 75 84 82 81 0 75 87 84 85 100 0 90 43 43 43 0 92 32 35 32 0 77 80 78 77 0 76 84 81 82 Input line voltage V Load torque 480V FR1 480V FR2 480V FR3 480V...

Страница 75: ...1 without NEMA 1 kit dimension drawing DM1 PRO FR1 Dimension Drawing 180 7 087 72 2 835 152 5 984 5 2 0 205 57 5 2 264 140 5 512 C 50 1 969 D 50 1 969 B 0 A 0 70 2 756 Minimum Dimensions A Free space...

Страница 76: ...kit dimension drawing DM1 FR1 Dimension Drawing 178 5 7 028 72 2 835 152 5 984 57 5 2 264 140 5 512 5 2 0 205 C 50 1 969 D 50 1 969 Minimum Dimensions A Free space on the left of drive B Free space o...

Страница 77: ...kit dimension drawing DM1 PRO FR2 Dimension Drawing 180 7 087 220 8 661 109 4 291 90 5 3 563 207 8 150 5 5 0 217 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free spac...

Страница 78: ...1 kit dimension drawing DM1 FR2 Dimension Drawing 180 00 220 8 661 109 4 291 90 5 3 563 207 8 150 5 5 0 217 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free space on...

Страница 79: ...kit dimension drawing DM1 PRO FR3 Dimension Drawing 260 10 236 130 5 118 180 7 087 116 4 567 247 9 724 5 5 0 217 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free spac...

Страница 80: ...kit dimension drawing DM1 FR3 Dimension Drawing 179 7 047 260 10 236 130 5 118 116 4 567 247 9 724 5 5 0 217 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free space on...

Страница 81: ...1 kit dimension drawing DM1 PRO FR4 Dimension Drawing 195 7 677 184 7 244 300 11 811 160 6 299 281 11 063 6 0 236 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free spac...

Страница 82: ...1 kit dimension drawing DM1 FR4 Dimension Drawing 195 7 677 184 7 244 300 11 811 160 6 299 281 11 063 6 0 236 D 50 1 969 C 50 1 969 Minimum Dimensions A Free space on the left of drive B Free space on...

Страница 83: ...um Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without option card A 70mm for drive with optio...

Страница 84: ...FR1 With NEMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive with...

Страница 85: ...mum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without option card A 70mm for drive with opti...

Страница 86: ...R1 With NEMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive witho...

Страница 87: ...With NEMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without...

Страница 88: ...EMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without option...

Страница 89: ...With NEMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without...

Страница 90: ...NEMA 1 Kit Dimension Drawing 130 5 122 260 10 244 126 2 4 972 432 66 17 047 2 22 5 0 887 3 28 3 1 115 116 4 570 247 9 732 Minimum Dimensions A Free space on the left of drive B Free space on the righ...

Страница 91: ...With NEMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without...

Страница 92: ...EMA 1 Kit Dimension Drawing Minimum Dimensions A Free space on the left of drive B Free space on the right of drive C Free space above drive D Free space below drive Notes A 0 for drive without option...

Страница 93: ...r 575 V series It is recommended that transient surge suppression be installed on the line side of this equipment and be rated 600 V phase to ground suitable for Overvoltage Category III and shall pro...

Страница 94: ...0 5 1 2 10 10 7 1 0 8 28 16 0 5 1 5 1 73 0 2 4 5 0 5 FR3 DM1 32025 25 3 32 2 8 10 10 5 1 2 8 10 14 2 1 6 28 16 0 5 1 5 1 73 0 2 4 5 0 5 FR4 DM1 32032 32 2 48 3 4 25 33 3 73 8 16 14 2 1 6 28 16 0 5 1 5...

Страница 95: ...l not be triggered if the two STO inputs become consistent within 200 ms Table 37 Safety related parameters Operation mode FR1 4 Operation mode High demand Safety integrity level SIL 2 SIL CL 2 System...

Страница 96: ...Vdc 480V series 300 880 Vdc STO activation STO1 STO2 0 1 5 Vdc STO deactivation STO1 STO2 16 28 Vdc U V W PE M 3 L1 L2 L3 PE EMC Up side IGBT driver SMPS STO channel 1 STO channel 2 Power Board Contr...

Страница 97: ...stable speed electrical power drive systems Part 5 2 Safety requirements functional IEC 61800 5 1 2007 A1 2016 as far as applicable Adjustable speed electrical power drive systems Part 5 1 Safety requ...

Страница 98: ...r supply 24VDC must be implemented at application level according to applicable requirement standards e g ISO 13849 2 2012 WARNING Any circuit connected to the STO terminal block shall be SELV or PELV...

Страница 99: ...EN September 2020 www eaton com Figure 33 Thermistor STO dry contact wiring diagram Requirements of proof test This device shall be subjected to a proof test at least once every 20 years Please contac...

Страница 100: ...Systems Part 5 1 Safety Requirements Electrical Thermal and Energy Edition 1 and CSA C22 2 No 274 17 Adjustable Speed Drives Edition 2 See UL report for additional details CE Declaration of Conformity...

Страница 101: ...91 Notes POWERXL SERIES VFDS MN040060EN September 2020 www eaton com Notes...

Страница 102: ...Cleveland OH 44122 United States Eaton com 2020 Eaton All Rights Reserved Printed in USA Publication No MN040060EN TBG001507 September 2020 Eaton is a registered trademark All trademarks are property...

Отзывы: