background image

OXALIS

   

TM396 – XF-XP-XT LW UL ISS.A

 

Unit B Sutton Parkway 

Oddicroft Lane, Sutton-in-Ashfield 

NG17 5FB 

 

 

XF, XP & XT Series 

Flame Proof Camera Housings 

& Pan Tilt Units 

Class I Division 1 Group B, C, D 

Class II Division 1 Group E, F, G 

Class I Zone 1 IIB + Hydrogen 

-60°C to +70°C 

 

Class I Division 1 Group A, B, C, D 

Class II Division 1 Group E, F, G 

Class I Zone 1 IIC 

-20°C to +70°C 

 

File No. E477542 

 

 

 

 

 

 

 

 

 

 

 

Installation & Maintenance Instructions 

 

The contents of this manual should be read and understood before attempting to connect or operate the 

equipment. This manual should be kept for future reference. 

This equipment shall be installed in accordance with the latest local/national codes of practice, and 

standards e.g. UL 1203 Edn.5, CSA22.2 No30-M1986 Edn1 reaffirmed 2012, CSA C22.2 No25-1966 

reaffirmed 2014, CSA C22.2 No 60065-03 Edn.1, UL60065 Edn.7 

 

Whilst every effort has been made to ensure that all information in this document is correct at the time of 

publication, due to our policy of continuous improvement, the company reserves the right to change any 

information contained herein without notice. 

 

 

Содержание OXALIS

Страница 1: ...anual should be read and understood before attempting to connect or operate the equipment This manual should be kept for future reference This equipment shall be installed in accordance with the latest local national codes of practice and standards e g UL 1203 Edn 5 CSA22 2 No30 M1986 Edn1 reaffirmed 2012 CSA C22 2 No25 1966 reaffirmed 2014 CSA C22 2 No 60065 03 Edn 1 UL60065 Edn 7 Whilst every ef...

Страница 2: ...nstallation 11 3 3 1 Sunshield Installation 11 3 3 2 Washer Nozzle Installation 12 3 4 Electrical Installation 13 3 4 1 Electrical Installation XP XT Integrated Pan Tilt housing assembly 13 3 4 2 XP XT Common Connection Examples 15 3 4 3 Electrical Installation XF Series Units 16 3 4 4 XF Series Common Connection Examples 17 4 0 Maintenance 18 4 1 Corrosion Protection 18 5 0 Labelling Marking 18 6...

Страница 3: ...EATON Installation Maintenance Instructions TM396 XF XP XT LW UL ISS A 3 P a g e Amendment Record Issue Date Details of Amendment A 20 05 2021 First Issue ...

Страница 4: ...nt is designed to satisfy the requirements of UL60065 7th Edition 2013 07 24 CSA C22 2 No 60065 03 2012 08 01 Safety Requirements ANNEX II of ATEX directive 94 9 EC 7 Be aware that aggressive substances may require extra protection of the equipment to maintain its integrity and explosion protection 8 The equipment may need additional means of protection if it is to be installed in locations where ...

Страница 5: ...a housings XP Pan Tilt units with integral base section for cable connections XT Pan Tilt units with integral base section for cable connection and a secondary linked housing for an integrated illuminator The XF fixed housings comprise a single tube section enclosure with either cable entries in the rear cover or in the side model dependent The XP and XT units have a single cable entry into the fi...

Страница 6: ...on and maintenance purposes we recommend the following hand tools Voltmeter Ohmmeter Torque wrench kit Set to 7 5Nm Hex Allen wrench bits of 5 4 3 1 5mm Spanners 5 5mm 8mm 10mm 13mm A F Screw drivers Standard and Phillips head Pliers Side cutting and long nose 2 4 Recommended Spares For Maintenance purposes we recommend the following spares OX10 00188 EX Base Cable Entry Seal Kit 50 8x3 53 O ring ...

Страница 7: ...ing either side of the T body The camera housings must not be used for lifting To avoid damage to the unit DO NOT ATTEMPT to rotate the camera housings by hand The units should not be handled using direct contact with ferrous metal equipment see section 4 1 for details 3 2 Mounting Ensure the desired mounting surface can support four times the combined weight of the complete unit Do not stand or p...

Страница 8: ...ON Installation Maintenance Instructions TM396 XF XP XT LW UL ISS A 8 P a g e Fig 1 XP40VE Example XP Series unit showing base mount fixing points for an L Body PTZ unit Fig 2 BPW6500 Wall Mounting Bracket ...

Страница 9: ...four 4 M6 Threaded fixing points Fig 5 The type and size of these fixings to be supplied by the user installer and must be suitable for the specific installation requirements To gain flexibility of the cameras view direction one of the EATON range of fixing brackets is needed These comprise of the BFP00SW Swivel joint Fig 6 the BFW32SW Fig 7 or a combination of the BFW5000 and BFP00SW Figs 3 6 Dep...

Страница 10: ...Maintenance Instructions TM396 XF XP XT LW UL ISS A 10 P a g e Fig 5 XF60VN Example XF Series unit showing mount plate fixing points Fig 7 BFW32SW Swivel Joint Pole Top Adaptor Fig 6 BFP00SW Swivel Joint Pole Top Adaptor ...

Страница 11: ...re supplied with the camera system and should be positioned as detailed below To mount the sunshields first they must be positioned correctly and fixed with a Nylon spacer between the sunshield and the camera housing the M5 A4 Button head screws supplied must have the red fiber washer fitted before fixing the sunshield Fig 8 9 Sunshields can have four equally sized fixings at each corner Fig 8 or ...

Страница 12: ...ioned to allow the cleaning fluid to reach the camera window when the wash command is sent The supplied washer nozzle brackets are specific to housing type and are delivered pre aligned for effective use Fig 10 When a wash command is sent to the camera the unit will move to a factory set position allowing the screen to be washed For non continuous rotation pan and tilt units and fixed housings the...

Страница 13: ... internal objects and fittings WARNING THE BASE ENTRY COVER AND GLANDS SHOULD NEVER BE REMOVED WHEN THE UNIT IS ENERGISED WAIT 5 MINUTES AFTER DE ENERGISING 1 Always use colour coded conductors or other identification of conductors for ease of wiring and identification of function later 2 Keep a wiring diagram with the system for later use and reference 3 Provision is made for one or two cable ent...

Страница 14: ...unction Box Dual cable entry Caution should be taken when removing and replacing the base cover to avoid trapping internal cables WARNING THE CABLE ENTRY FLANGE SHOULD NEVER BE REMOVED WHEN THE UNIT IS ENERGISED Loosen the grub screw Before attempting to unscrew the cover The 2x M5 Btn Hd Screws are to aid rotation of the cover ...

Страница 15: ...EATON Installation Maintenance Instructions TM396 XF XP XT LW UL ISS A 15 P a g e 3 4 2 XP XT Common Connection Examples Always refer to project specific drawings and information ...

Страница 16: ... is fitted first take note of the parked position of the wiper arm and then remove it by loosening the M4 Cap Head screw that clamps to the wiper shaft Keep the wiper and nylon washer safe for refitting This is best done with the sunshield removed Fig 14 Removing the Front Window Cover Remove the front window cover by first removing the 5 x M6 Cap Head screws and then carefully extracting the cove...

Страница 17: ...EATON Installation Maintenance Instructions TM396 XF XP XT LW UL ISS A 17 P a g e 3 4 4 XF Series Common Connection Examples Always refer to project specific drawings and information ...

Страница 18: ...ery Inspection carry out the following Clean the exterior of the unit Check the O ring weather seals and replace if necessary Check and if necessary replace the washer nozzle Check and if necessary replace the window wiper blade assembly Use only Eaton approved spare parts 4 1 Corrosion Protection All external metal components are produced from 316L Stainless Steel however if the units are not cor...

Страница 19: ...ation Maintenance Instructions TM396 XF XP XT LW UL ISS A 19 P a g e Certification label IIB Hydrogen Certification Label IIC Coding Class I Div 1 Group B C D Class II Div 1Groups E F G T135 C IP67 T Class T4 T5 T6 ...

Страница 20: ...Kg depending on model Stand alone housing 12 22Kg depending on model Mounting Pan Tilt with housing 4 x M10 Cap Head screws on 182mm PCD Standalone housing Depending on mounting brackets Supply voltage 24VAC 50 60Hz or 100 to 230VAC with integral transformer Power consumption Max 120 Watts depending on model Cable Entry Options NPT thread or NPT thread using a suitably certified reducer and depend...