EATON
Installation & Maintenance Instructions
IMI+70-XP-XT Iss_A
© 2020, Eaton
Page 14
4.0
Maintenance
Please read and be familiar with the instructions in this manual before servicing the any parts of
these camera units.
Regular maintenance to the X Series of camera units is important to safeguard their use in harsh and
hazardous environments. Please refer to the maintenance recommendations in the ANNEX to this
manual.
4.1
Corrosion Protection
All external metal components are produced from 316L Stainless Steel, however, if the units are not
correctly maintained, handled and cleaned there is the possibility of mild discolouration due to normal
oxidation.
If ferrous metal equipment is used when handling the units, small ferrous deposits could be left on the
stainless steel, or if ferrous metal particles come to rest upon the units from nearby works, this can
cause accelerated corrosion of the ferrous deposits and discolour the units by normal oxidation.
In atmospheres that have high levels of corrosive particles, the units should be cleaned every 3 to 4
months using only EATON recommended cleaning products and procedures. (contact EATON for
details)
EATON takes no responsibility for oxidisation due to a failure to comply with the correct cleaning
procedures.
5.0
Labelling
The certification & rating labels are etched on 316 stainless steel and fixed to the units using stainless
steel rivets. The contents of the label will be in ENGLISH.
The label shows:
A - Name of Manufacturer
B – Model Type
C - Operating Voltage
D - EX ratings,
E - ATEX Certificate & IECEX certificate numbers
F - Serial Number,
G - Notified Body Number
Refer to controlled Annex at the end of this manual for full label marking details.
6.0
Specifications, Technical Data
Construction:
Stainless Steel AISI 316L
Ingress Protection rating:
IP 66/7 Max Weight:
Pan & Tilt with housing:
33-62Kg depending on model
Mounting:
Pan & Tilt with housing:
4-x M10 fixings on 182mm PCD
Supply voltage:
24VAC, 50/60Hz or
100 to 230VAC with integral transformer
Power consumption:
Max 120 Watts depending on model
Cable Entry
M25 x1.5 ISO thread, or M20 using an
Ex d certified reducer, dependent on
specification at order.