3.4
Electrical Installation
Electrical installation and servicing should only be carried out by qualified service personnel and in
accordance with all local/national codes of practice and standards e.g. EN 60079- 14:2014 and IEC
60079-14:2013.
Due to the large number of possible configurations, this manual only covers the standard
installation of the units.
For detailed connection and configuration of units, the installer should refer to individual project
specific drawings and information.
Units can be supplied, as required, with either AC or DC 24V, 110V or 230V Supply; all ±10% The
units should only be powered from the specified voltage, no allowance is made for varying voltage
supply.
WARNING:
IRREPARABLE DAMAGE TO THE UNIT WILL RESULT FROM AN
INCORRECT POWER SUPPLY VOLTAGE
3.4.1
Electrical Installation XP & XT Integrated Pan, Tilt, housing assembly
For safe access to electrical connections with the XP and XT series cameras, refer to ATEX controlled
certified ANNEX to this manual.
CAUTION SHOULD BE TAKEN WHEN REMOVING AND INSERTING ANY ENTRY COVERS/ FLANGES/
CABLE GLANDS TO AVOID INTERNAL CABLES BECOMING SNAGGED OR STRETCHED
ON INTERNAL OBJECTS AND FITTINGS.
WARNING - THE BASE ENTRY COVER AND GLANDS SHOULD NEVER BE REMOVED WHEN THE UNIT
IS ENERGISED. WAIT 5 MINUTES AFTER DE-ENERGISING.