Ceiling Microwave presence/absence detector 12-24V AC/DC 

MPAD-C-A 12-24V 

Microwave Sensor 

Detects movement within the unit’s detection range, 
allowing load control in response to changes in occupancy. 

IR Receiver 

Receives control and programming commands from an  
IR (infrared) handset. 

Light Level Sensor 

Measures the overall light level in the detection area  

Status LEDs 

The LED flashes 

R

ed to indicate the following: 

Power Input & Output Connector 

Used to connect power to the unit and to connect a 
switched load. 

Switch Input Connector 

Two input terminals can be used to manually override the 
lights on or off. 

Walk Test LED active 

        

when movement is detected

 

Valid setting received 

 

Retaining Spring 

Retaining Spring 

Power Input & 
Output 
Connector

 

Switch Input 

Connector

 

Front features 

The MPAD-C-A 12-24V Microwave presence detector 
provides automatic control of low voltage loads including 
lighting and BMS systems with optional manual control. The 
MPAD-C-A 12-24V detects movement using a highly 
sensitive microwave detector. This works by emitting low 
power microwave signals and measuring the reflections as 
the signals bounce off moving objects.  
Functioning as a presence detector, the unit can turn lights 
on when a room is occupied and off when the room is 
empty. Optional settings allow lights to be turned off in 
response to ambient daylight. 
The MPAD-C-A 12-24V has a unique adjustable sensor 
head that allows the area of detection to be optimised for 
the application.  
All functionality is fully programmable using an IR handset. 

Sensor Lens 

which covers... 

 

Microwave Sensor 

IR Receiver 

Light Level Sensor 

Status LEDs 

Mounting Bezel 

Product Guide 

Содержание MPAD-C-A

Страница 1: ...pring Power Input Output Connector Switch Input Connector Front features The MPAD C A 12 24V Microwave presence detector provides automatic control of low voltage loads including lighting and BMS syst...

Страница 2: ...d In either case sensitivity to movement of the Microwave sensor can be adjusted using the Sensitivity parameter HINT To assist in setting the Sensitivity turn on the Walk Test LED which will flash re...

Страница 3: ...when movement is detected The unit is now ready for programming Power up test procedure Choosing a Suitable Location The detector should be sited so that the occupants of the room fall inside the det...

Страница 4: ...before affixing the cable clamp The clamp MUST clamp the outer sheath s only Bend cores as shown Wire stripping details Flush fixing Surface fixing Head locking 1 3 2 4 Hole 30mm MAX 1 2 Remove metal...

Страница 5: ...old the R Read button for more than 1 second The handset will click every time a parameter is received The device will show multiple flashes of its LED All of the values will be shown against the para...

Страница 6: ...llows the output to turn off when movement ceases but must be manually turned on first Shift Use this button to select the settings in red and blue signified by the Shift 1 and Shift 2 LEDs Number of...

Страница 7: ...ction to be implemented with a lux off level set When the button is pressed the lights will go on regardless of ambient light level However if there is sufficient ambient light they will turn off agai...

Страница 8: ...allowable frequency of operation of this product is different depending on region Please select the correct order code using the table below Suffix Region Frequency blank UK China India Middle East M...

Отзывы: