background image

Eaton

1000 Eaton Boulevard

Cleveland, OH 44122

United States

Eaton.com

Eaton’s Power Systems Division

2300 Badger Drive

Waukesha, WI  53188

United States

Eaton.com/cooperpowerseries

© 2017 Eaton

All Rights Reserved

Printed in USA

Publication No. MN280079EN

KA2048-610 Rev.01 

May 2017

Eaton is a registered trademark.

All trademarks are property  

of their respective owners.

For Eaton’s Cooper Power series product 

information  

call 1-877-277-4636 or visit:  

www.eaton.com/cooperpowerseries.

!

SAFETY

FOR LIFE

Содержание KME6-1875-1

Страница 1: ...m 6 recloser control KME6 1875 1 KME6 1875 2 and KME6 1875 3 fiber optic converter kits installation instructions COOPER POWER SERIES Reclosers MN280079EN Effective May 2017 Supersedes March 2003 S280 70 6 ...

Страница 2: ...RPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In no event will Eaton be responsible to the purchaser or user in contract in tort including negligence strict liability or other wise for...

Страница 3: ... iii Product information 1 Introduction 1 ANSI standards 1 Quality standards 1 Acceptance and initial inspection 1 Handling and storage 1 Description 1 Installation 1 KME6 1875 1 fiber optic converter kit for form 6 pole mount control 1 KME6 1875 2 fiber optic converter kit for form 6 yard mount control 4 KME6 1875 3 fiber optic converter kit for form 6 rack mount control 6 ...

Страница 4: ...ltage lines and equipment and support our Safety For Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around high and low voltage lines and equipment G103 3 WARNING Before installing operating maintaining or testing this equipment carefully read and understan...

Страница 5: ... file a claim with the carrier immediately Handling and storage Be careful during handling and storage of the kit to minimize the possibility of damage If the kit is to be stored for any length of time prior to installation provide a clean dry storage area Description The fiber optic converter accessory provides a permanent link for two way real time serial communications with a remote terminal un...

Страница 6: ... switch is in the OFF position Note N The mode switch enables the repeater function in the REP position and disables it in the OFF position CAUTION Equipment damage Always wear a grounding wrist strap to control static electricity before handling circuit boards Failure to use this strap may result in circuit board damage T253 1 5 Mount the fiber optic converter on the mounting stud inside the back...

Страница 7: ... Service Information MN280077EN Form 6 Microprocessor Based Pole Mount Recloser Control Installation and Operation Instructions for the procedure Return the Control to Service Table 1 KME6 1875 1 form 6 pole mount recloser control fiber optic converter kit parts Item Description Quantity 1 Fiber optic converter assembly 1 2 Nut hex machine screw 10 32 KEPS stainless steel 1 TB1 1 2 3 5 7 9 11 13 1...

Страница 8: ...de switch is in the OFF position Note N The mode switch enables the repeater function in the REP position and disables it in the OFF position CAUTION Control damage De energize both ac and dc power prior to removing or installing any internal connections or circuit boards in the control Failure to comply can result in damage to the control T241 1 CAUTION Equipment damage Always wear a grounding wr...

Страница 9: ...mply can result in misoperation unintended operation equipment damage and personal injury G119 2 10 Return the Form 6 yard mount recloser control to service Refer to Service Information MN280076EN Form 6 Microprocessor Based Yard Mount Recloser Control Installation and Operation Instructions for the procedure Return the Control to Service TB1 1 2 3 5 7 9 11 13 15 17 19 4 6 8 10 12 14 16 18 CI1 CI2...

Страница 10: ...andling circuit boards Failure to use this strap may result in circuit board damage T253 1 5 Connect the loose end of the fiber optic power cable Choose one of these two options OPTION 1 Connect to customer supplied 24 Vdc non polarized power source or OPTION 2 Connect to Terminal Block TB5 A Connect the black wire to TB5 5 B Connect the red wire to TB5 4 Note N The RS 232 and power cables are six...

Страница 11: ...I 3 4 I 5 6 V 1 2 V 3 4 V 5 6 V1 I SEF FUSE 10 AMP FUSE 10 AMP TB5 1 5 2 4 INPUT POWER AUXILIARY POWER 28 VDC 9 Pin Cable Connected to RS 232 Port OPTION 2 Fiber Optic Power Cable Connected to Terminal Block TB5 Black Wire Connected to TB5 5 Red Wire Connected to TB5 4 Fiber Optic Converter Assembly Grounding Stud Ground to Earth with customer supplied 6 grounding lug 6 Foot Cable Length 6 Foot Ca...

Страница 12: ...ates Eaton com cooperpowerseries 2017 Eaton All Rights Reserved Printed in USA Publication No MN280079EN KA2048 610 Rev 01 May 2017 Eaton is a registered trademark All trademarks are property of their respective owners For Eaton s Cooper Power series product information call 1 877 277 4636 or visit www eaton com cooperpowerseries SAFETY FOR LIFE ...

Отзывы: