background image

 

HVAC Application

 

2

H-Max HVAC Drives

 

    MN04008004E—September 2011    www.eaton.com

 

Example of Control Connections

 

Control Connections 

Slot A

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

A

+10V

AI–1+

V

in

AI–2+

AI–2–

24V

out

GND

DIN1

DIN2

DIN3

24V

out

GND

DIN4

DIN5

DIN6

AO–1+

AO–1–

DATA–

Reference Output
Analog Input Voltage (Range 0–10 Vdc)
(can be programmed to current 4–20 mA)
Analog Output Common (Ground)

Analog Input Common
PI Setpoint or Feedback

Control Voltage Output (0.1A max.)

I/O Ground

START/STOP (Contact closed = start)

External Fault (Closed = fault)

Run Interlock Permissive IP Interlock
(Closed = OK)

DIN1–DIN6 Common

Control Voltage Output (0.1A max.)

I/O Ground

Fire Mode (Contact closed = fire mode)

Force Bypass (Contact closed = bypass)

DIN1–DIN6 Common

Output Frequency (0–20 mA)

Analog Output Common (Ground)

RS-485 DATA–

Speed Select 0–100% (Preset speed)

U (T1)

V (T2)

W (T3)

R+

R–

L1

L2

L3

Three-Phase Input
Input
(Single-Phase not available)

Three-Phase

Output

DB

Chopper

Terminal

Factory Default Signal

Resistor

Analog Input Current (Range 4–20 mA)
(can be programmed to voltage 0–10 Vdc)
PI Setpoint or Feedback

B

DATA+

RO1 Bypass Run

RO2 Drive Run

RO3 Fault

24 Vdc/8A
250 Vac/8A
125 Vdc/0.4A

Relay Board 1
Default Signal

21

22

23

24

25

26

32

33

Slot B

Analog

RS-485 DATA+

Factory
Jumper

COM

CMB

30

24 Vdc

in

Auxiliary Input Voltage

Circuit

Breaker

Optional

Motor

RJ-45

BACnet/IP Ethernet Industrial Protocol
Modbus/TCP Transmission Control Protocol (Ethernet Based)

5% DC Link
Reactor

Programmable BACnet, 
Modbus, FLN, N2

ON
CURRENT
CURRENT
CURRENT

RS485
AO1
AI2
AI1

OFF

VOLTAGE
VOLTAGE
VOLTAGE

Test

Содержание H-Max Series

Страница 1: ...H Max HVAC Drives Quick Start Guide Effective September 2011 Supersedes August 2011...

Страница 2: ......

Страница 3: ...RTICULAR PURPOSE OR MERCHANTABILITY OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCU...

Страница 4: ...77 ETN CARE 386 2273 8 00 a m 6 00 p m EST FAX 800 752 8602 After Hours Emergency 800 543 7038 6 00 p m 8 00 a m EST If you are in the U S or Canada and have OI or PLC questions you can take advantage...

Страница 5: ...or Fieldbus Control page for easy operation and monitoring of the most essential values Run interlock input damper interlock Drive will not start before this input is activated Different pre heat mod...

Страница 6: ...ode Force Bypass Contact closed bypass DIN1 DIN6 Common Output Frequency 0 20 mA Analog Output Common Ground RS 485 DATA Speed Select 0 100 Preset speed U T1 V T2 W T3 R R L1 L2 L3 Three Phase Input I...

Страница 7: ...the EMEA Keypad Functionality is quite similar The EMEA keypad does not support the bypass functionality commonly used in the United States US Keypad Buttons EMEA Keypad Buttons Switching Between Driv...

Страница 8: ...r current location The Status field gives information about the present status of the drive See Control Connections on Page 2 Main Menu Using the Graphical Keypad Editing Values Change value of a para...

Страница 9: ...is always used as control place while in hand control Hand control has higher priority than auto control Therefore if for example bypassed by parameter P2 1 17 through digital input while in Remote th...

Страница 10: ...other control places or reference values are used the display will show Frequency reference which is not editable The other values on the page are Multimonitoring values You can choose which values ap...

Страница 11: ...talled Now the Startup Wizard is done The Startup Wizard can be re initiated by pressing and holding the back reset button for two seconds The Startup Wizard will appear upon next power up 1 Run Start...

Страница 12: ...dBack1 Srce AI2 AI1 Not Used ProceDataIn8 ProceDataIn7 ProceDataIn6 ProceDataIn5 ProceDataIn4 ProceDataIn3 ProceDataIn2 ProceDataIn1 AI6 AI5 AI4 AI3 2 Process Unit Selection Several Selections 3 Proce...

Страница 13: ...d Menus Monitor Basic Diagnostics Active Faults Timer Functions Reset Faults Multimonitor Fault History Parameters Basic Parameters Total Counters Analog Inputs Trip Counters Digital Inputs Software I...

Страница 14: ...Motor Nom Freq 111 P2 1 15 Motor Nom Speed 112 P2 1 16 MotorPowerFactor 120 P2 1 17 Current Limit 107 P2 1 18 Service Factor 1357 Parameter Group 2 2 Analog Inputs Analog Input 1 P2 2 1 1 AI1 Signal s...

Страница 15: ...5 AI6 Custom Max 203 P2 2 6 6 AI6 Filter Time 200 Parameter Group 2 2 Basic Parameters Basic P2 2 7 1 Ref Scale Min 1307 P2 2 7 2 Ref Scale Max 1308 Parameter Group 2 3 Digital Inputs Digital Input 1...

Страница 16: ...0054 P2 4 1 6 AO1 Invert 10060 Parameter Group 2 5 Digital Outputs Digital Output 1 P2 5 1 1 RO1 function 11001 P2 5 1 2 RO1 Invert 11020 P2 5 1 3 RO1 ON delay 11002 P2 5 1 4 RO1 OFF delay 11003 Digit...

Страница 17: ...0 P2 6 1 15 S Ramp 2 Shape 501 Skip Frequencies P2 6 2 1 Range 1 Low Lim 509 P2 6 2 2 Range 1 High Lim 510 P2 6 2 3 Range 2 Low Lim 511 P2 6 2 4 Range 2 High Lim 512 P2 6 2 5 Range 3 Low Lim 513 P2 6...

Страница 18: ...FieldbusComm Flt 733 P2 8 1 13 InputPhaseFault 730 P2 8 1 14 MotorStall Flt 709 P2 8 1 15 PID1 Supervision 749 P2 8 1 16 PID2 Supervision 757 P2 8 1 17 SlotCommFlt 734 P2 8 1 18 Preset Alarm Freq 183...

Страница 19: ...WakeUpLevel PID Controller 1 1018 P2 9 1 2 10 SP 1 boost PID Controller 1 1071 P2 9 1 2 11 SP 2 Source PID Controller 1 431 P2 9 1 2 12 SP 2 minimum PID Controller 1 1073 P2 9 1 2 13 SP 2 maximum PID...

Страница 20: ...2 1 9 Dead Band PID Controller 2 1637 P2 9 2 1 10 Dead band delay PID Controller 2 1638 PID Controller 2 Setpoints P2 9 2 2 1 Keypad SP 1 PID Controller 2 1640 P2 9 2 2 2 Keypad SP 2 PID Controller 2...

Страница 21: ...1097 P2 12 9 Bandwidth delay 1098 Parameter Group 2 13 Braking Braking P2 13 1 DC Brake Current 507 P2 13 2 DC Time Stop 508 P2 13 3 DC BrakeFreqStop 515 P2 13 4 StartMagnTime 516 P2 13 5 StartMagnCu...

Страница 22: ...l 2 1678 P2 16 2 5 Assign to channel Interval 2 1679 Interval 3 P2 16 3 1 ON Time Interval 3 1680 P2 16 3 2 Off Time Interval 3 1681 P2 16 3 3 From Day Interval 3 1682 P2 16 3 4 To Day Interval 3 1683...

Страница 23: ...in the Fault history Entering the Fault history and clicking OK on the selected fault shows the fault time data details Fault Code Fault ID Fault Name Possible Cause Remedy 1 1 Overcurrent hardware fa...

Страница 24: ...he software for example application has caused an overload situation The source of fault has been suspended Reset the fault and restart Should the fault re occur contact the distributor near you 609 M...

Страница 25: ...odel parameters 17 160 Motor underload Motor is underloaded Check load 19 180 Power overload short time supervision Drive power is too high Decrease load 181 Power overload long time supervision 25 Mo...

Страница 26: ...Slot A fault Defective option board or slot Check board and slot 1454 Slot B fault 1654 Slot D fault 1754 Slot E fault 65 1065 PC communication fault The data connection between the PC and frequency c...

Страница 27: ......

Страница 28: ...nsuring that reliable efficient and safe power is available when it s needed most With unparalleled knowledge of electrical power management across industries experts at Eaton deliver customized integ...

Отзывы: