12/12
Emergency On Call Service: Local representative (
http://www.eaton.com/moeller/aftersales
) or +49 (0) 180 5 223822 (de, en)
11/10 I
L05013003Z
Eaton Industries GmbH, Hein-Moeller-Straße 7-11, 53115 Bonn, Germany
© 2006 by Eaton Industries GmbH,
www.eaton.com/moeller/support
All Rights Reserved
Printed in Germany (11/10)
SmartWire-LED
Dimensions – Abmessungen – Dimensiones – Dimensioni –
Размеры
[mm
(inch)
]
a
OFF
Initialisation phase
b
GREEN permanent
Trouble-free operation at SmartWire bus possible, the stored setpoint and the current
actual configuration match. Data is exchanged via the SmartWire bus if the job is carried out via
easyNet or CAN.
c
GREEN flashing
SmartWire setpoint and actual configuration are different. Example: With the initial
commissioning if setpoint configuration has not been determined or stored yet.
d
GREEN fast flashing
Faulty SmartWire communication, at least one SmartWire station does not respond anymore
(power failure, cable breakage or fault).
a
AUS
Initialisierungsphase
b
GRÜN dauernd
Störungsfreier Betrieb am SmartWire-Bus ist möglich, die gespeicherte Soll- und die aktuelle
Istkonfiguration stimmen überein. Der Datenaustausch über den SmartWire-Bus findet statt,
wenn der Auftrag über easyNet oder CAN erfolgt.
c
GRÜN blinkend
SmartWire Soll- und Istkonfiguration sind verschieden. Beispiel: Bei der Erstinbetriebnahme,
wenn noch keine Sollkonfiguration ermittelt und gespeichert wurde.
d
GRÜN schnell blinkend
Gestörte SmartWire-Kommunikation, mindestens ein SmartWire Teilnehmer antwortet nicht
mehr (Spannungsausfall, Kabelbruch oder Defekt).
a
ARRET
Phase d’initialisation
b
VERT permanent
Fonctionnement sans défaut du bus SmartWire possible, les configurations consigne enregistrée
et réelle actuelle coïncident. L’échange de données par le bus SmartWire a lieu lorsque la tâche
est effectuée via easyNet.
c
VERT clignoteur
Les configurations SmartWire consigne et réelle sont différentes. Exemple : lors de la première
mise en service si la configuration consigne n’a pas encore été déterminée ni enregistrée.
d
VERT clignoteur rapide
Communication SmartWire défectueuse, au moins un participant SmartWire ne répond plus (cou-
pure de tension, rupture de câble ou autre défaut).
a
OFF
Fase de iniciación
b
VERDE continuo
Es posible el funcionamiento sin errores en el bus SmartWire, la configuración de consigna y
la configuración real actual coinciden. El intercambio de datos se produce mediante el bus Smart-
Wire, si la tarea se realiza mediante easyNet o CAN.
c
VERDE intermitente
La configuración de consigna y real SmartWire son distintas. Ejemplo: durante la primera puesta en ser-
vicio, si todavía no se ha determinado ni guardado ninguna configuración de consigna.
d
VERDE intermitente
rápido
Comunicación SmartWire defectuosa, como mínimo un participante SmartWire ha dejado de con-
testar (corte de corriente, rotura de cable o defecto).
a
OFF
Fase di inizializzazione
b
VERDE costante
E’ consentito il funzionamento libero da disturbi del bus SmartWire, la configurazione standard
memorizzata e la configurazione reale attuale corrispondono Lo scambio di dati avviene
attraverso il bus SmartWire quando l’ordine è eseguito attraverso easyNet o CAN.
c
VERDE lampeggiante
La configurazione standard e la configurazione reale sono diverse. Esempio: Alla prima messa in
servizio, se non è stata ancora rilevata e memorizzata nessuna configurazione standard.
d
VERDE lampeggiante
velocemente
Comunicazione SmartWire disturbata, almeno un utente SmartWire non risponde più
(interruzione dell’alimentazione, rottura di un cavo o guasto).
a
ВЫКЛ
Фаза инициализации
b
ЗЕЛЕНЫЙ светодиод
ровно светится
Корректная работа шины SmartWire bus, сохраненные параметры заданной величины
и текущей рабочей конфигурации совпадают. Обмен данными через шину SmartWire,
если работа выполнена через easyNet или CAN.
c
ЗЕЛЕНЫЙ светодиод
мигает
Сохраненные параметры заданной величины SmartWire и текущей конфигурации не
совпадают. Обмен данными через шину SmartWire, если работа выполнена через
easyNet или CAN. Пример: начальный запуск при неопределенной или несохраненной
конфигурации заданной величины.
d
ЗЕЛЕНЫЙ светодиод
быстро мигает
Некорректная связь по SmartWire, как минимум одна станция SmartWire более не
отвечает (сбой питания, разрыв кабеля).
d
t
b
t
c
t
a
t
35 mm
(1.
3
8”)
90 mm
(
3
.54”)
4.5 mm
(0.18”)
105 mm
(4.1
3
”)