e. After releasing the keys, the display alternates
between the menu title and the current menu
item setting. After pressing any key, only the
menu item setting is displayed.
f. Pressing the right key will switch the menu
item setting to the next value.
If figures are to be input (e.g. when setting the
scaling factor), select first the decade using
the left key, and then set the value using the
right key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title “EndPro” allows the user,
when selecting “Yes”, to exit the programming
menu and to store the new values.
If “no” is selected, the programming routine is
repeated, the latest values set remaining
active. They can now be checked again or
modified.
3. Programming routine
The first menu item is the selection of the basic
operating mode, which determines the functions
of the device.
Electronic totalizer and frequency
meter
1. Description
• 6-digit totalizer and frequency meter
• Red LED display, character height 8 mm
[0.31 in.]
• Display range 0 – 999 999
• Lead zero blanking
• Programming via two setting keys on the front
side
• During programming, the display guides the
user with text prompts
• Value conversion and display in 1/s or 1/min
2. Inputs
INP A
Dynamic count/frequency input.
RESET
Dynamic RESET input. Linked in parallel to the
red RESET key. Resets the counter to zero.
3. Selection of the displayed value
Pressing the right key allows switching between
the totalizer display and the frequency meter
display. Press the key briefly to display the cur-
rent function (“total” or “tacho”) for 2 seconds.
If, during this period of time, the right key is
pressed a second time, the device switches to
the next function and displays a confirmation
(“total” or “tacho”) for 2 seconds. Then, the
value of the selected function is displayed.
4. Programming routine
The programmable parameters of the device are
described below, in the order in which they can
be set. The device is fully programmed after one
pass of the routine.
The first values stated correspond to the factory
settings.
2
MN05401010E
Operating mode adding
counter and frequency
meter, continued in point 4
below
Operating mode display
counter with 2 totalizing
ranges, continued in point
4 on page 4
Operating mode totalizer
and time meter, continued
in point 4 on page 7
Operating mode time
meter with 2 time ranges,
continued in point 4 on
page 9
- Subject to change without prior notice -
E5524E0402:
basic operating mode
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 2