background image

 

 
 

 
 
 

 

BEETLE /iSCAN EASY eXpress

+

 

Self-Checkout System 

 
 
 
 
 
 
 
 
 
 
 

Integration Guide (November 2018) 

Содержание BEETLE/iSCAN EASY eXpress+

Страница 1: ...BEETLE iSCAN EASY eXpress Self Checkout System Integration Guide November 2018...

Страница 2: ...ixdorf International GmbH 2018 All rights including rights to full or partial translation reprinting and transmission or copying by any means are reserved Offenders are liable to payment of damages Al...

Страница 3: ...h sides status indicator coupon box and base plate 15 9 1 5 Pillar mounting of 19 BEETLE iScan EASY eXpress and optional scale platform 16 9 1 6 Wall mounting of 15 BEETLE iScan EASY eXpress 16 9 1 7...

Страница 4: ......

Страница 5: ...ill find further important details in relation to installation in the Installation Guide for the BEETLE iSCAN Express on the Diebold Nixdorf website An angled power cable is required both for integrat...

Страница 6: ...5 C Relative humidity 5 r h 1 g m 3 85 r h 25 g m 3 Temperature fluctuation 0 5 K min max 7 5K 30 min Air pressure 106 78 kPa 78kPa corresponds to the air pressure for installation at approx 2000m abo...

Страница 7: ...BEETLE iSCAN EASY eXpress Integration Guide 3 3 Dimensions all values in mm 3 1 Rear of 15 and 19 version...

Страница 8: ...Integration Guide BEETLE iSCAN EASY eXpress 4 3 2 15 version...

Страница 9: ...BEETLE iSCAN EASY eXpress Integration Guide 5 3 3 15 version with tabletop display...

Страница 10: ...Integration Guide BEETLE iSCAN EASY eXpress 6 3 4 19 version 3 5 19 version with tabletop display...

Страница 11: ...BEETLE iSCAN EASY eXpress Integration Guide 7 3 6 Openings on the underside 3 7 Device with open door Service area Grip area of lock...

Страница 12: ...ay be installed vertically or tilted at an angle of up to 23 from the vertical Danger owing to ingress of liquids In case of vertical assembly in a restaurant environment a suitable mechanism must be...

Страница 13: ...uncovered to ensure adequate ventilation This prevents the temperature increasing excessively Even if you plan to integrate the device make sure to maintain the minimum distances stated below and ens...

Страница 14: ...eXpress 10 Observe the specified minimum distances to ensure proper ventilation Always keep the ventilation slots free of obstruction to ensure adequate air circulation and avoid overheating 15 versi...

Страница 15: ...iSCAN EASY eXpress Integration Guide 11 6 Suspending the system 4 positions for securing with screws with a diameter of 6mm 4 positions for se curing with hooks additional fixing with screws is nec e...

Страница 16: ...are openings on the underside of the device to the right and left which are sealed by covers One of the covers allows cable feed with edge protection The covers are interchangeable Covers for cabling...

Страница 17: ...es two M4 screw threads on either side of the body for attaching add ons such as brackets for handheld scanners advertising media etc The M4 screw threads must not be used under any circumstances for...

Страница 18: ...Integration Guide BEETLE iSCAN EASY eXpress 14 9 Pillar and wall mounting 9 1 Dimensions in mm 9 1 1 Optional base plate 9 1 2 Pillar drill template...

Страница 19: ...press Integration Guide 15 9 1 3 Pillar mounting with 15 BEETLE iScan EASY eXpress 9 1 4 Pillar mounting of 19 BEETLE iScan EASY eXpress with optional basket shelf on both sides status indicator coupo...

Страница 20: ...Integration Guide BEETLE iSCAN EASY eXpress 16 9 1 5 Pillar mounting of 19 BEETLE iScan EASY eXpress and optional scale platform 9 1 6 Wall mounting of 15 BEETLE iScan EASY eXpress...

Страница 21: ...BEETLE iSCAN EASY eXpress Integration Guide 17 9 1 7 Wall mounting of 19 BEETLE iScan EASY eXpress...

Страница 22: ...oor mounting must be carried out by a trained engineer after assessing and evaluating the structural conditions on site Materials required depending on the substrate 4x M10 anchor bolts 4x DIN 933 M10...

Страница 23: ...s Do not mark any drilling points near the cable feed Attention The kiosk must be screwed tightly to the floor so that it cannot tilt over Drill the four holes in the floor using a 12mm drill and inst...

Страница 24: ...ews in half way Attention Two people are needed to position the kiosk on the pillar 8 First insert the closed BEETLE iS CAN EASY eXpress below into the sheet metal tabs of the pillar adapter 1 Now rai...

Страница 25: ...ies in free drill holes on the pillar from the inside For more information about con necting the cables see the BEETLE iSCAN EASY eXpress Installation Guide on the Diebold Nixdorf website 11 Mount the...

Страница 26: ...e BEETLE iSCAN EASY eXpress 22 12 Insert the rear panel and secure by screwing in 13 Unlock the BEETLE iSCAN EASY eXpress and open the door Now insert the front cover and close and lock the BEETLE iSC...

Страница 27: ...structural conditions on site 1 Follow steps 1 2 in Section 9 2 1 2 Position the base plate above the floor outlet so that the ca bles can pass through the hole in the center of the base plate The pil...

Страница 28: ...equired cables through the opening into the interior of the pillar 3 Follow steps 6 13 in Section 9 2 1 9 4 Installing the basket shelf at front 1 To install the basket shelf at the front at the stand...

Страница 29: ...et shelf on the angle brackets and push these toward the rear until the shoulder screw on the right hand side submerges into the key contour 1 Now pull the shelf forward again right up to the key cont...

Страница 30: ...shelf at the standard height 535 mm clip the shelf into the mounting grid so that the upper hook is located in the 12th opening from below 2 Insert the two safety plates from the inside as shown in th...

Страница 31: ...e on the angle brackets without load plate and push these to the rear until the shoulder screw on the right side submerges into the key contour 1 Now pull the scale forward again right up to the key c...

Страница 32: ...n the cable for the scale controller upward in the rear area of the pillar and secure it from the outside in a free drill hole using cable ties 6 Now feed the cable to the BEETLE iS CAN EASY eXpress i...

Страница 33: ...rity scale at the standard height 535 mm first clip the scale without the load plate into the mounting grid so that the upper hook is mounted in the 12th opening 1 Insert the two safety plates from th...

Страница 34: ...Integration Guide BEETLE iSCAN EASY eXpress 30 3 Now feed the cable to the BEETLE iS CAN EASY eXpress in the top area 4 Place the load plate on the scale...

Страница 35: ...Insert the mounting frame into the pillar so that the lower fixing hole corresponds to the bottom drill hole in the perforated grid of the mount ing pillar 2 Now screw in the four M6x10 cheese head sc...

Страница 36: ...gration Guide BEETLE iSCAN EASY eXpress 32 3 Secure the cable in free drill holes us ing cable ties and feed the cable to the BEETLE iSCAN EASY eXpress 4 Insert the coupon box 1 close 2 and finish 3 1...

Страница 37: ...lower two drill holes on the rear of the pillar 2 Place the base plate on the two screws and slide the base down to the floor 1 Now tighten the screws 2 3 Insert the rear panel and secure with a safet...

Страница 38: ...num profiles remove in the direction of the arrows 7 Connect the aluminum profiles with out gaps using four M4x6 round head screws 8 Place the connected aluminum pro file with status indicator on the...

Страница 39: ...35 10 Position the outer aluminum profile and lock in place 11 Now secure the cable from the status indicator cable inside the pillar to a free drill hole in the perforated grid using cable ties and f...

Страница 40: ...engineer after as sessing and evaluating the structural conditions on site Two people are required to perform the installation The wearing of safety shoes is obliga tory 1 Clip the coupon printer shel...

Страница 41: ...nting dimensions in mm Use four screws of max 6mm in diameter and suitable dowels depending on the structural condi tions on site The 19 BEETLE iScan EASY eXpress weighs approx 30kg while the 15 BEETL...

Страница 42: ...mount into the lower two screws through the keyholes and press downward to align all four holes in the wall mount to the dowels in the wall 3 Screw in the two missing screws and tighten all four scre...

Страница 43: ...sed BEETLE iSCAN EASY eXpress below into the sheet metal tabs of the pillar adapter 1 Then raise the BEETLE iSCAN EASY eXpress and clip into the upper snap hooks and screws of the pillar adapter 2 7 O...

Страница 44: ...Integration Guide BEETLE iSCAN EASY eXpress 40 10 Block diagram The optional components are highlighted in green...

Страница 45: ...Diebold Nixdorf D 33094 Paderborn Order no 01750301911A...

Отзывы: