8
MN05401010E
Time unit: seconds (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: minutes (reso-
lution depending on posi-
tion of the decimal point*)
Time unit: hours (resolu-
tion depending on posi-
tion of the decimal point*)
Time units:
Hours:Minutes:Seconds
(decimal point setting is
ignored)
4.8 Operating mode
(time meter)
*0, 0.1, 0.01, 0.001 means: time measurement in
0, 0.1, 0.01, 0.001 time units
4.9 Decimal point
(time meter)
The decimal point defines
the resolution of the pro -
gram med time unit.
0 1
0.0 1/10 (0.1)
0.00 1/100 (0.01)
0.000 1/1000 (0.001)
4.11 End of programming
The programming routine
is repeated once more.
The values set until now
can be checked and
modified.
The programming routine
will be exited and all
values set will be stored
as new parameters.
Afterwards the device is
ready for operation.
4.10 RESET mode
(time meter)
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
MN05401010E.qxd:MN05401010E 7/31/12 9:10 AM Page 8