SIMEX
®
USER MANUAL for
time counter
type:
SLC-457
firmware version:
1.01
or higher
Read the user's manual carefully before starting to use the unit.
Producer reserves the right to implement changes without prior notice.
13.12.2005
V.1.2
Страница 1: ...L for time counter type SLC 457 firmware version 1 01 or higher Read the user s manual carefully before starting to use the unit Producer reserves the right to implement changes without prior notice 1...
Страница 2: ...4 bri parameter 14 7 3 5 Scod parameter 15 7 4 MENU STRUCTURE 15 8 THE MODBUS PROTOCOL HANDLING 16 8 1 LIST OF REGISTERS 16 8 2 TRANSMISSION ERRORS DESCRIPTION 17 8 3 EXAMPLES OF QUERY ANSWER FRAMES...
Страница 3: ...troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate standards and regulations concerning safety and be equipped with adequate anti o...
Страница 4: ...an be changed from 1200 to 115200 baud SLC 457 has additional sensor supply output non separated stabilized 24V DC 5 max 100 mA 3 TECHNICAL DATA Power supply voltage depending on version External fuse...
Страница 5: ...orque 0 5 Nm Max connection leads diameter 2 5 mm2 Safety requirements according to PN EN 61010 1 1999 PN EN 61010 1 A2 1999 installation category II pollution degree 2 voltage in relation to ground 3...
Страница 6: ...t serial number on the housing and report the damage to the manufacturer Attached with the unit please find warranty user s manual for SLC 457 unit device 4 2 CONNECTION METHOD Caution Installation sh...
Страница 7: ...the unit must be applied To avoid the unit of improper indications keep recommendations listed below Avoid common parallel leading of signal cables and transmission cables together with power supply c...
Страница 8: ...evel RESET counter clearing rising logical edge COM common terminal All connections must be made while power supply is disconnected Depend on version 85 230 260V AC DC or 19 24 50V DC 16 24 35V AC Fig...
Страница 9: ...nit is operating Excessively high temperatures cause faster ageing of the internal components and shorten the fault free time of unit operation In cases where the unit gets dirty do not clean with sol...
Страница 10: ...RINCIPLE OF OPERATION After turning the power supply on device ID and software version are showed on the display next the controller goes to the counting mode After that unit goes to counting mode res...
Страница 11: ...requirements it is redcommended to use IR remote controller for menu settings configuration IR remote controller is available optionally as additional equipement The device menu allow user to set all...
Страница 12: ...exits the menu mode and returns to the counting mode only if no parameters are in editing mode 7 2 PARAMETERS EDITION To start edition of any parameter user should select name of desired one using v b...
Страница 13: ...of password If entered password is correct first menu position will be displayed else warning Err and unit returns to counting mode Due to problem with direct displaying of m letter it is exchanged wi...
Страница 14: ...via RS 485 interface This additional delay allows the device to work with poor RS converters which do not works properly on baud rates higher than 19200 This parameter can be set to one of values Std...
Страница 15: ...password the access to the menu is possible by the one use password To get this password please contact witch Marketing Division Please set new user password immediately after use of the one use passw...
Страница 16: ...minutes Range from 0 to 100 hours 60000 minutes Write of any value to this register clears counter 02h Yes Counter value hours minutes decimally Value of this register equals hours 100 minutes e g 310...
Страница 17: ...decimal Field description ADDR Device address on modbus network FUNC Function code REG H L Starting address address of first register to read write Hi and Lo byte COUNT H L No of registers to read wri...
Страница 18: ...C BYTE C DATA H L CRC L H 01 03 02 04 D2 3A D9 DATA H L 04D2h 1234 counter value 12 34 12 hours 34 minutes 4 Try to write improper value to register 22h baud rate ADDR FUNC REG H L DATA H L CRC L H 01...
Страница 19: ...er s value Desc page rinP Activation of RESET input oFF 13 RS 485 interface configuration rS menu Addr Device address 0 13 bAud Baud rate 9 6 14 mbAc Blocking of access to the configuration registers...
Страница 20: ...SIMEX SIMEX Sp z o o ul Wielopole 7 PL 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex com pl e mail info simex com pl...