1 General
1.1 Parameter Groups
DC1…E1 Variable Frequency Drives
11/16 MN040022EN
www.eaton.com
5
1 General
1.1 Parameter Groups
The DC1 variable frequency drive’s functions are configured with the use of
parameters. These parameters are subdivided into four groups (P00-01 to
P00-50, P-01 to P-14, P-15 to P-59, and P-60 to P-68):
Table 1: Parameter Groups
Default settings
By default (= unit as supplied), only parameter group 1 (“Basic”) will be
accessible.
Extended parameter set
Level 2 (“Extended”) can be accessed by using parameter P-14 to enter
the correct password.
The default password is:
•
Access to level 2: 101
Users can change this password as required:
•
Password for Level 2 with: P-37
•
Advanced parameter set:
Can be accessed by entering the password for level 2 (P-37 + 100)
Parameter group
Theme
P00-01 – P00-50
Monitor
P-01 – P-14
Basic
P-15 – P-59
Extended
P-60 – P-68
Advanced
→
The following page (“Menu structure“) features a diagram
showing how to switch between parameter groups.