FOR BEST RESULTS

•  Install the motion sensor/transmitter 8-12 feet 

  above the ground. (Motion sensor is less sensitive 

  above 12 feet.)
•  Locate motion sensor so motion moves laterally or

  towards the detection zone (Fig. 1).
•  Locate sensor away from heat producing sources to

  prevent false triggering. Also be very careful not to 

  include objects such as windows, white walls and

  water in the detection zone.
•  Locate sensor away from moving objects such as 

  trees, large shrubs and street traffic.
•  Do not install more than one motion activated 

  floodlight on one wall switch.

MOUNTING AND WIRING YOUR FIXTURE

NOTE:

 Universal coverplate mounts to recessed or 

surface mounted standard junction boxes (Fig. 2).  

Junction box must be at least 1-1/2 inch in depth for  

proper installation for recessed mount application.

NOTE:

 Fixture can be wall or eave mounted (Fig. 3).

NOTE:

 For best performance when installing more than 

one Precision Plus Doppler Radar™ fixture:

 

• Two or more units mounted side by side (facing the 

    same direction) should be at least 17 feet apart.
  • Two units facing each other should be mounted at 

    least 100 feet apart.

 WARNING: Risk of electric shock. Disconnect 

power at fuse or circuit breaker before installing 

or servicing.
1.  Turn off the power at the main fuse/breaker box.
2. 

Connect the black wire from the fixture (A) to the 

black house supply wire and the white wire from 

the fixture (A) to the white supply wire using the 

wire nuts (D) provided. Attach the ground wire 

coming from your house to the copper ground wire 

from the fixture (A) using wire nut (D) provided. If no 

house ground wire is available, attach the copper 

ground wire from the fixture (A) to the junction box 

if it is metal and grounded. If junction box is not 

metal and no house ground wire is available, an 

alternative ground source must be used for safe 

operation (Fig. 4).

3. 

Attach fixture to the junction box with two of the

      screws (D) provided. Either (2) #6 or (2) #8 screws
      will work with most standard junction boxes. Make
      sure that all screws are tightly secured.

4. 

Apply silicone caulk around the edges of the 

coverplate to provide a watertight seal from rain 

and moisture.

5. 

Insert lampholder gaskets (B) into lampholder 

assembly, tightly against lampholder, and screw 

bulbs into each lampholder (Fig. 6). (Do not 

overtighten bulbs.)

6. 

Turn on power at main fuse/breaker box.

AIMING THE LIGHT

Loosen the knob on the side of the lampholder. 

Tilt lampholder up or down to desired position, then 

retighten knob.

 WARNING: Deviation from the assembly 

instructions may result in a risk of electric shock.

OPERATING YOUR FIXTURE

1.

  Turn the arrow on the MODE knob to “TEST” for test 

mode (Fig. 7).

2. 

Turn the arrow on the SENSITIVITY knob to a middle 

point between “+” and “–”.

3. 

Turn on the power to the fixture. Allow fixture to 

warm up approximately 90 seconds before testing. 

(Lights may or may not come on during warm-up 

period; this is normal.)

4.

  Aim sensor toward the general direction that motion 

will be coming from. Maintain at least 1 inch of 

clearance between sensor head and lamps. Always 

position the sensor head with control switches 

facing toward the ground.

NOTE: (Sensor Head Placement)

 For optimum 

detection, you may have to experiment with aiming and 

settings. Each location will be different and your terrain 

may affect the angle your sensor needs. Adjusting the 

angle will change your area of detection. Here are some 

general guidelines to help with setup:

 

• 8 ft.–12 ft. above the ground is a good range for 

    the placement of your fixture.

 

• For an 8 ft. mounting height, placing the sensor at 

    a 5° angle below horizontal should work well for 

    most locations (Fig. 8).

 

• If the fixture is mounted higher, the angle of the

    sensor below horizontal should increase.

5.  

Walk through the detection zone at the farthest 

distance you want your detector to detect motion.

6.

   Adjust the SENSITIVITY knob until you get desired 

results. For more range, aim sensor slightly upward. 

For less range, aim sensor head slightly downward. 

Lights will turn OFF 4 seconds after motion stops.

7.

   Adjust the “Auto” MODE knob to a time selection from 

 

1min–12min, depending on how many minutes you want 

 

the fixture to stay on after motion is detected. At dusk, 

 

the photo control will activate your fixture to operate 

 

according to the settings chosen.

NOTE:

 Decreasing the SENSITIVITY will decrease the 

distance the unit can detect.

NOTE:

 During daylight hours, the red LED indicator light 

will flash when motion is detected. This is normal.

SELECTING YOUR DESIRED FEATURE

 Problem

  

Cause / Solution

 Light 

does not  

  come on with  
  motion at night.

No power to the fixture.
  •  Check if circuit breaker tripped.
  •  Confirm wall switch is ON.
Bulb is faulty.
  • Replace bulb.
Surrounding external ambient light is too bright. (If so, the unit may

think it is daytime.)
  •  Re-aim the head.
  •  Relocate or reposition the unit away from the light.

TURN OFF POWER BEFORE CONTINUING

Wiring to the unit is loose.
  •  Check wiring, and reconnect if necessary using wire 

    nuts (E) provided.

TROUBLESHOOTING

 

Mode of 

MODE Knob 

How to Set

 

Operation 

Adjustment 

Power Switch

MODE knob arrow

points to TEST.

Test Setting

Lights should turn ON with

motion both day and night.

Lights should turn OFF

after 4 seconds.

Wall Switch Setting

(connected to fixture)

Keep wall switch

in ON position.

Motion Activated Setting “Auto”

Lights should turn ON with

motion only at night and

should turn OFF after

1-12 min. of no motion.

“Auto” MODE knob arrow

points to a time 

selection within the

1m-12m time range.

Keep wall switch in

ON position. 

Keep the power 

to the fixture ON.

Dusk-to-Dawn Setting

(activated only at night)

Lights should stay ON from

dusk to dawn and then reset

to motion activated 

setting after 6 hours.

MODE knob arrow

points to a time selection

within the 1m-12m

time range.

Turn the power 

OFF-ON-OFF-ON

within 3 seconds; light will

go into override mode.

Return to 

Motion Activated Setting 

from any of

the above settings.

“Auto” MODE knob arrow

points to a time selection

within the 1m-12m

time range.

Turn the power OFF

for at least 90 seconds

and then back ON.

Round

1-1/2 in.

Octagonal

1-1/2 in.

2

Wall mount

Eave mount

3

1

A

D

D

D

4

A

5

B

B

6

7

A

8

C

C

C

C

Содержание ALL-PRO MS185DW

Страница 1: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Страница 2: ...during warm up period this is normal 4 Aim sensor toward the general direction that motion will be coming from Maintain at least 1 inch of clearance between sensor head and lamps Always position the...

Страница 3: ...moins de 5 cm 2 po de mat riaux combustibles CONDUCTEURS D ALIMENTATION DE 90 C MIN Pour assurer le fonctionnement et la protection contre les d g ts il faut diriger les Light comes on for no apparent...

Страница 4: ...vitez d obstruer les orifices d a ration Installez conform ment aux instructions du fabricant Ne l installez pas pr s d une source de chaleur quelconque comme des radiateurs des registres d air chaud...

Страница 5: ...mural raccord l appareil d clairage Laissez l interrupteur mural allum S LECTION DE LA FONCTION SOUHAIT E La fl che du bouton MODE pointe vers TEST essai Les lampes r gl es au mode TEST essai Les lam...

Страница 6: ...a casa no tiene alambre neutral disponible conecte el alambre neutral de la l mpara a la caja de conexi n si es de metal Una fuente neutral alternativa se debe utilizar en caso Montaje de pared Montaj...

Страница 7: ...eben encenderse por el movimiento tanto en el d a como en la noche Las luces deben apagarse despu s de 4 segundos La perilla de MODO apunta hacia la TEST Ajuste de interruptor de pared conectado al ac...

Страница 8: ...por bombillas de reemplazo corrosi n o decoloraci n de los componentes de lat n no est n cubiertos por esta garant a LIMITACI N DE RESPONSABILIDAD EATON NO SER RESPONSABLE LEGAL EN NING N CASO DE DA O...

Отзывы: