Questions?/Des questions?/¿Preguntas? 1-800-334-6871 [email protected]
1
PACKAGING CONTENTS/CONTENU DE L’EMBALLAGE/CONTENIDO DEL PAQUETE
Instruction Manual/Instrucciones
CAUTION
• Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids
the warranty.
• Fixture must be mounted to a grounded recessed junction box marked for use
in wet locations.
• Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
• Fixture should be installed by persons with experience in household wiring or by a
qualified electrician. The electrical system, and the method of electrically connecting
the fixture to it, must be in accordance with the National Electrical Code and local
building codes.
• Do not allow sensor head to touch light housing – maintain at least 1 in. space
between fixture and sensor.
• Keep away from flammable objects. Do not position fixture within
2 in. of any combustible materials.
• MINIMUM 90°C SUPPLY CONDUCTORS.
• For proper operation and protection against damage, the motion
sensor head adjustment knobs must be facing the ground.
• Do not use this apparatus near water.
• Clean only with a dry cloth.
• Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
• Do not install near any heat sources such as radiators, heat registers, stoves or other
apparatus (including amplifiers) that produce heat.
• Only use attachments/accessories specified by the manufacturer.
• This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation. Under Part 15 of the FCC Rules, any changes or
modifications to the motion detector described in this instruction sheet that are
not expressly approved by Eaton could void the user’s authority to operate
the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ITEMS REQUIRED
(Purchase separately)
• Phillips screwdriver
• Outdoor weatherproof silicone caulking
• (2) 100 watt (MAX) PAR 38 floodlight bulbs
NOTE:
This fixture was designed to work with up to 150 watt maximum PAR halogen flood
bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used.
Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion
sensing function of your fixture and are not recommended. To meet ENERGY STAR
®
requirements, maximum total lamp wattage can not exceed 250 watts.
HOW IT WORKS
PIR does a good job of detecting lateral motion across the 180°
range of detection. Precision Plus Doppler Radar™ does an
excellent job detecting motion towards and away from the unit.
Both systems combined provide enhanced accuracy and complete
coverage within the detection range. Motion from any direction will
trigger your floodlight—even during hot or cold temperature extremes.
IMPORTANT SAFETY INSTRUCTIONS
When using product, basic precautions should always be followed, including the following:
• Heed all warnings, including below warnings AND those included on product.
• Save these instructions and warnings.
• For outdoor use only.
• cETLus LISTED for wet location.
• Disassembling your fixture will void the warranty.
• Your fixture is prewired and preassembled for easy installation.
• Read and follow these instructions.
• To reduce the risk of a burn during relamping, disconnect power supply to the unit
before relamping.
• Bulb gets HOT quickly!
• The bulb and fixture get extremely hot during use. Disconnect power and allow fixture
to cool before changing bulb or handling fixture.
• Always replace bulb with the same wattage or lower wattage than marked. Installing
a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will
void the warranty. (Maximum 150 watt PAR halogen bulb.) .
MS185D (Bronze)
ENGLISH
Up to
70 feet
180 degrees
B.
(2) Lampholder gaskets
(2) Juntas obturadoras
del receptáculo
(2) Joints statiques de douille
WARNING
A.
Motion detector
and light fixture
Detector de movimiento
y accesorio
Luminaire avec détecteur
de mouvement
D.
(3) Wire nuts
(3) Conectores del cables
(3) Capuchons de connexion
C.
(2) #6 and (2) #8 mounting screws
(use the size that fits your junction box)
(2) Tornillos #6 y (2) tornillos #8 de montaje (utilice el
tamaño que mejor se adecue a su caja de conexión)
(2) vis nº 6 et (2 )vis nº 8 pour boîte de jonction (choisissez
la dimension convenant à votre boîte de jonction)
MS185DW (White)