CAUTION

•  Connect fixture to a 120 volt, 60 Hz power source. Any other connection voids 

the warranty.

•  Fixture must be mounted to a grounded recessed junction box marked for use 

in wet locations.

•  Suitable for wall mount or eave mount only. NOT suitable for ground mount installation.
•  Fixture should be installed by persons with experience in household wiring or by a 

qualified electrician. The electrical system, and the method of electrically connecting 

the fixture to it, must be in accordance with the National Electrical Code and local 

building codes.

•  Do not allow sensor head to touch light housing – maintain at least 1 in. space 

between fixture and sensor.

•  Keep away from flammable objects. Do not position fixture within 

2 in. of any combustible materials.

•  MINIMUM 90°C SUPPLY CONDUCTORS.
•  For proper operation and protection against damage, the motion 

sensor head adjustment knobs must be facing the ground.

•  Do not use this apparatus near water.
•  Clean only with a dry cloth.
•  Do not block any ventilation openings. Install in accordance with the manufacturer’s 

instructions.

•  Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including amplifiers) that produce heat.

•  Only use attachments/accessories specified by the manufacturer.
•  This device complies with Part 15 of the FCC Rules. Operation is subject to the 

following two conditions: (1) This device may not cause harmful interference, and  

(2) this device must accept any interference received, including interference that  

may cause undesired operation. Under Part 15   of the FCC Rules, any changes or  

modifications to the motion detector described in this instruction sheet that are  

not expressly approved by Eaton could void the user’s authority to operate  

the equipment.

   NOTE:

 This equipment has been tested and found to comply with the limits for  

 

  a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are  

 

  designed to provide reasonable protection against harmful interference in a  

 

  residential installation. This equipment generates, uses and can radiate radio  

 

  frequency energy and if not installed and used in accordance with the instructions,  

 

  may cause harmful interference to radio communications. However, there is no  

 

  guarantee that interference will not occur in a particular installation. If this equipment  

 

  does cause harmful interference to radio or television reception, which can be  

 

  determined by turning the equipment off and on, the user is encouraged to try to  

 

  correct the interference by one or more of the following measures:

       - Reorient or relocate the receiving antenna.

 

  -  Increase the separation between the equipment and receiver.

 

  -  Connect the equipment into an outlet on a circuit different from that to which the  

 

    receiver is connected.

 

  -  Consult the dealer or an experienced radio/TV technician for help.

ITEMS REQUIRED

 

(Purchase separately)

•  Phillips screwdriver
•  Outdoor weatherproof silicone caulking
•  (2) 100 watt (MAX) PAR 38 floodlight bulbs

NOTE:

 This fixture was designed to work with up to 150 watt maximum PAR halogen flood 

bulbs. For improved energy efficiency, lower wattage PAR halogen flood bulbs may be used. 

Compact Fluorescent (CFL) bulbs contain electronics which may interfere with the motion 

sensing function of your fixture and are not recommended. To meet ENERGY STAR

®

    

requirements, maximum total lamp wattage can not exceed 250 watts.

HOW IT WORKS

PIR does a good job of detecting lateral motion across the 180° 

range of detection. Precision Plus Doppler Radar™ does an 

excellent job detecting motion towards and away from the unit.

Both systems combined provide enhanced accuracy and complete

coverage within the detection range. Motion from any direction will

trigger your floodlight—even during hot or cold temperature extremes.

IMPORTANT SAFETY INSTRUCTIONS

  When using product, basic precautions should always be followed, including the following:

•  Heed all warnings, including below warnings AND those included on product.
•  Save these instructions and warnings.
•  For outdoor use only.
•  cETLus LISTED for wet location.
•  Disassembling your fixture will void the warranty.
•  Your fixture is prewired and preassembled for easy installation.

•  Read and follow these instructions.
•  To reduce the risk of a burn during relamping, disconnect power supply to the unit 

before relamping.

•  Bulb gets HOT quickly!
•  The bulb and fixture get extremely hot during use. Disconnect power and allow fixture 

to cool before changing bulb or handling fixture.

•  Always replace bulb with the same wattage or lower wattage than marked. Installing 

a bulb of a higher wattage could create a fire hazard. Use of a higher wattage bulb will 

void the warranty. (Maximum 150 watt PAR halogen bulb.) .

MS185D (Bronze)

 ENGLISH

Up to

70 feet

180 degrees

B.

  (2) Lampholder gaskets

  (2) Juntas obturadoras 

   del receptáculo
   (2) Joints statiques de douille

WARNING

A.

  Motion detector 

  and light fixture
  Detector de movimiento 

  y accesorio
  Luminaire avec détecteur  
  de mouvement

D.

   (3) Wire nuts

   (3) Conectores del cables 
  

(3) Capuchons de connexion

C.

  (2) #6 and (2) #8 mounting screws 

   (use the size that fits your junction box)
   (2) Tornillos #6 y (2) tornillos #8 de montaje (utilice el  

   tamaño que mejor se adecue a su caja de conexión) 
  

(2)  vis nº 6 et (2 )vis nº 8 pour boîte de jonction (choisissez  

   la dimension convenant à votre boîte de jonction) 

MS185DW (White)

Содержание ALL-PRO MS185DW

Страница 1: ...is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect...

Страница 2: ...during warm up period this is normal 4 Aim sensor toward the general direction that motion will be coming from Maintain at least 1 inch of clearance between sensor head and lamps Always position the...

Страница 3: ...moins de 5 cm 2 po de mat riaux combustibles CONDUCTEURS D ALIMENTATION DE 90 C MIN Pour assurer le fonctionnement et la protection contre les d g ts il faut diriger les Light comes on for no apparent...

Страница 4: ...vitez d obstruer les orifices d a ration Installez conform ment aux instructions du fabricant Ne l installez pas pr s d une source de chaleur quelconque comme des radiateurs des registres d air chaud...

Страница 5: ...mural raccord l appareil d clairage Laissez l interrupteur mural allum S LECTION DE LA FONCTION SOUHAIT E La fl che du bouton MODE pointe vers TEST essai Les lampes r gl es au mode TEST essai Les lam...

Страница 6: ...a casa no tiene alambre neutral disponible conecte el alambre neutral de la l mpara a la caja de conexi n si es de metal Una fuente neutral alternativa se debe utilizar en caso Montaje de pared Montaj...

Страница 7: ...eben encenderse por el movimiento tanto en el d a como en la noche Las luces deben apagarse despu s de 4 segundos La perilla de MODO apunta hacia la TEST Ajuste de interruptor de pared conectado al ac...

Страница 8: ...por bombillas de reemplazo corrosi n o decoloraci n de los componentes de lat n no est n cubiertos por esta garant a LIMITACI N DE RESPONSABILIDAD EATON NO SER RESPONSABLE LEGAL EN NING N CASO DE DA O...

Отзывы: